Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T08CM00643
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/17/2008 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
09/15/2008 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* OK TEMP C OF O ACCESSIBLE ROUTES SHOWN ON PLAN IS NON-COMPLIANT |
|
08/28/2008 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* OK TCO WHEN I GET PLUMBING FINAL 1. PLUMBING FINAL AND BACTERIA REPORT REQUIRED 2. ACCESSIBLE ROUTES SHOWN ON PLAN IS NON-COMPLIANT A. REVISE PLAN TO SHOW NO CHANGE OF OCCUPANCY AND USE IBC 3409.7 (1) TO SHOW COMPLIANCE OR B. REVISE PLAN AND PROVIDE ACCESSIBLE ROUTE PER 3409.6 OR C. FIX AREAS SHOWN AS ACCESSIBLE ON PLAN |
|
08/26/2008 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* CORRECTION NOT MADE DATED 6/16/08 |
|
06/16/2008 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. CLARIFY ACCESSIBLE ROUTE FROM STREET (CHAPTER 11 IBC) AND ACCESSIBLE PARKING. PARKING MUST COMPLY WITH ANSI 117.1 YOUR PLANS INDICATE 100% ACCESSIBILITY 2. CAUTION FINAL CLEAR SPACE FROM CENTER OF TOILET TO FINISHED WALL MUST BE 16"-18" |