Permit: T08CM00587

Parcel: 122184340


Addresses:

3501 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
08/03/2010 MECHANICAL - INTERMEDIATE Approved
05/13/2010 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
04/09/2010 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) ROOF TOP CURBS OK WITH SOUND ATTENUATION
04/06/2010 MECHANICAL - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) ISOLATE ABS FROM METAL STUDS
2) SUPPORT PIPING AT EACH CHANGE OF DIRECTION OR ELEVATIONS AND AT THE END OF GRANCHES, THEN NO MORE THAN 4' BETWEEN HANGERS. SUPPORT AT EACH FLOOR WITH MID STORY GUIDES.
3) 2ND FLOOR DRAIN DUMPS INTO 1ST FLOOR VENT
4) MAXIMUM 24" FOR TAIL PIECE
5) WATER TEST ON D---- OK
6) OK TO INSULATE HOT AND RETURN
7) WATER PRESSURE TEST OK