Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T08CM00587

Parcel: 122184340


Addresses:

3501 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
08/09/2010 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
08/03/2010 EXCAVATION/LAYOUT REBAR & ZON Cancelled IVRS - RI canceled
05/25/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) TRASH ENCLOSURE FOOTINGS-OK TO POUR PROGRESS AREAS
05/24/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) STEM WALL FOOTINGS N.E., EAST, S.E. ALONG PROPERTY LINE-OK TO POUR PROGRESS AREAS EXCEPT: DO NOT POUR PORTION CONTAINING NEIGHBORING UTILITY LINES (SEWER LINES)
04/23/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) SCREEN WALL FOOTING APPROX 75 L.F.; SE CORNER OF SITE OK TO POUR PROGRESS AREAS
04/09/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) NORTH WEST PORTION OF SCREEN WALL FOOTINGS-OK TO POUR
04/07/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
10 PIER WALL COLUMN FOOTINGS; APPROX. 110'
SCREEN WALL FOOTINGS OK TO POUR PROGRESS AREAS
03/30/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) COMPRESSOR PAD ON ROOF PER DETAIL #260 ON REVISED SHELL BLDG PLANS-OK TO POUR PAD
02/18/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) COLUMN FOOTINGS-DRY PACKED-15 COLUMNS (SE PORTION)
02/10/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 11 AT LIGHT POLE CAISSON FOOTINGS-DETAILS #A, A1 OK TO POUR FOOTINGS (PAGE E-7)
01/28/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) COLUMN FOOTINGS (DRY-PACK) H 1-2.1; J/2-2.1, J/2-2.8 OK TO POUR FOOTINGS WHEN DRY
12/24/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 3 COLUMN FOOTINGS (6 #5'S EACH WAY) SOUTHEAST AND MID STAIRS AREA-OK TO POUR FOOTINGS
12/18/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) ELEVATOR PIT AND SUMP PIT; DETAILS #108 & 109 PAGE S3.0 OK TO POUR PROGRESS AREAS
12/01/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) COLUMN FOOTINGS GL 3/A-D; F/3-3.3; 3/F-G; G/2.7, A/1.1-2.2 (4) OK TO POUR PROGRESS AREAS
11/30/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) COLUMN FOOTINGS: GL G.1/4; F2/C6; F2/C1; H/4; P/4-5.5; F2/C7 (3) OK TO POUR PROGRESS AREAS
11/25/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) LINE 1/D-P; 3 F4/C1; 3 F3/C1; 1 F1/C5 FOOTINGS; LINE 3/L-N; 1-F4/C1, 1-F3/C1, LINE H.6/3.5 1 AT F3/C1; 1 AT F1/C5; LINE J/5 1 F5/C2; LINE 5/K-L 2 AT F4/C1 FOOTINGS; LINE H/6 1 AT F3/C1; LINE H.6/7-K/7 2 AT F3/C1 FOOTINGS-OK TO POUR PROGRESS AREAS
11/19/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) COLUMN FOOTINGS C1/F4 (2) LINE K/2.1, L/2.1; C1/F4 LINE G.1/2.1; 4.1/2.1; C4 J.2/2.8-2.1 (2); C4 H.1/2.1 (1); C1/F3 LINE K/3 (1); C1/F3 LINE H.6/3.5 (1); F/8 FOOTING CONTAINS C4 FOOTINGS (3) OK TO POUR PROGRESS AREAS
11/18/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) FOOTINGS AT LINES B/1-2.2; B/1.3; F6, F2; COLUMN FOOTINGS C1/F4 LINE C/2.1, F5/C1 LINE D/2.1; F5/C LINE E/2.1; FOOTING F6 LINES N/7-5.1; F2/C1 LINE N/4 OK TO POUR PROGRESS AREAS