Inspection Status: Approved
Inspection History: VIOL - MEANS OF EGRESS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/13/2007 | VIOL - MEANS OF EGRESS | Approved | 28. TFC 1025.1 General emergency escape and rescue. Is required in all sleeping areas. 1. MOVE FURTURE TO CREATE PATH TO WINDOWS |
|
| 04/13/2007 | VIOL - MEANS OF EGRESS | Approved | THIS PROPERTY HAS BEEN APROVED TO HAVE A HAVE A SAFE DISPERSAL AREA AND TO BLOCK THE EXIT DISCHARGE TO A PUBLIC WAY. ALL PROVSIONS FOR CODE 1023.6 MUST BE MAINTAINED AND MAY BE RESENDED FOR CAUSE BY ANY INSPECTOR. IFC 2003 1023.6 Access to a public way. The exit discharge shall provide a direct and unobstructed access to a public way. Exception: Where access to a public way cannot be provided, a safe dispersal area shall be provided where all of the following are met: 1. The area shall be of a size to accommodate at least 5 square feet (0.28 m2) for each person. 2. The area shall be located on the same property at least 50 feet (15 240 mm) away from the building requiring egress. 3. The area shall be permanently maintained and identified as a safe dispersal area. 4. The area shall be provided with a safe and unobstructed path of travel from the building. |