Case: T07FR00718
Case Details
Entered Date:
04/13/2007
Applicant:
JUVERA MARY INEZ
Description:
Full fire inspection check list used
Completed Inspections
Case Status: COMPLETE
Case Number: T07FR00718
Case Description: INSPECTION
Total Completed Inspections - 9
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/13/2007 | VIOL - COMPRESSED GASES | SHIGGINB | Approved | 36.TFC 3004.1 O2 storage and Use Can be on a 45 degree, Must be secured w/ straps or rack No smoking signs must be posted on front door. 1. SECURE O2 BOTTLES |
| 04/13/2007 | VIOL - MEANS OF EGRESS | SHIGGINB | Approved | THIS PROPERTY HAS BEEN APROVED TO HAVE A HAVE A SAFE DISPERSAL AREA AND TO BLOCK THE EXIT DISCHARGE TO A PUBLIC WAY. ALL PROVSIONS FOR CODE 1023.6 MUST BE MAINTAINED AND MAY BE RESENDED FOR CAUSE BY ANY INSPECTOR. IFC 2003 1023.6 Access to a public way. The exit discharge shall provide a direct and unobstructed access to a public way. Exception: Where access to a public way cannot be provided, a safe dispersal area shall be provided where all of the following are met: 1. The area shall be of a size to accommodate at least 5 square feet (0.28 m2) for each person. 2. The area shall be located on the same property at least 50 feet (15 240 mm) away from the building requiring egress. 3. The area shall be permanently maintained and identified as a safe dispersal area. 4. The area shall be provided with a safe and unobstructed path of travel from the building. |
| 04/13/2007 | VIOL - MEANS OF EGRESS | SHIGGINB | Approved | 28. TFC 1025.1 General emergency escape and rescue. Is required in all sleeping areas. 1. MOVE FURTURE TO CREATE PATH TO WINDOWS |
| 04/13/2007 | VIOL - BUILDING SVCS & SYSTEMS | SHIGGINB | Approved | 21.TFC 605.4 Multi-plugs and power-taps UL listed,No end to end, home made. 1. REMOVE ALL MULIT -PLUG ADAPTER THAT DON'T HAVE SURGE PROTECTION |
| 04/13/2007 | VIOL - BUILDING SVCS & SYSTEMS | SHIGGINB | Approved | 20. TFC 605.5 Extension cords Grounds, used as permanent wiring, run under carpet, attached to walls can be replaced w/ power strip that has overcurrent protection. 1. REMOVE EXTE. CORD AND REPLACE POWER TAP W/ SURGE PROTECTION |
| 04/13/2007 | VIOL - FIRE PROTECTION SYSTEMS | SHIGGINB | Approved | 34. TFC 901.6 Extinguisher maintenance Inspected and tagged annually. 1. TAG AND SERVICE FIRE EXTEN. |
| 04/13/2007 | VIOL - FIRE PROTECTION SYSTEMS | SHIGGINB | Approved | 16.TFC 907.3.1.8 Fire alarm systems Existing R4 must have a fire alarm system. Exception: Interconnected, hardwired w/ battery backup smoke alarms Use # 15 code reference for records. 1. NEED ALARM TESTING RECORDS ANNULLY. |
| 04/13/2007 | VIOL - PRECAUTION AGAINST FIRE | SHIGGINB | Approved | 7. TFC 307 BBQ 10’ from combustibles BBQ must be used 10’ from combustibles. Gas BBQs must stored 10’ away from combustibles. 1. MUST USE AND STORE BBQ 10' FROM BUILDING |
| 04/13/2007 | INSP - FULL | SHIGGINB | Approved | ASH LIC FOR 8 |