Case: T07FR00273

Parcel: 119010740


Addresses:

310 E BENSON HY

Inspection Status: Correction Required

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
02/06/2007 VIOL - MEANS OF EGRESS Correction Required 1. 1008.1.8.3 Locks and latches. 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25mm)high on a contrasting background.:
-Main front doors.

2. 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted.
- Remove the slide bolts on the active leaf of the exit doors.

3. Section 1014.2 Exit or exit access doorway arrangement. Required exits shall be located in a manner that makes their availability obvious. Exits shall be unobstructed at all times. Exit and exit access doorways shall be arranged in accordance with Sections
1014.2.1 and 1014.2.2.:
-maintain all exity free of obstructions including high chairs and other waiter equipment.