Permit: T07EL02201

Parcel: 133221060


Addresses:

7134 E LUANA PL

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
01/18/2008 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
01/10/2008 ELECTRIC - SERVICE UPGRADE Not ready for Inspection IVRS - Inspection :*
12/24/2007 ELECTRIC - SERVICE UPGRADE Not ready for Inspection IVRS - Inspection :*
1) EXPOSED NM CABLE
2) CORDS NOT ALLOWED AS PERMANENT WIRING 400.7
3) MARKING TAPE TO ENCIRCLE CONDUCTOR
4) PROPERLY LABEL CIRCUIT BREAKERS PER 405.4-EXISTING IS NOT A CIRCUIT LABEL
5) GROUND RODS TO BE MINIMUM 6' APART
6) PLEASE VERIFY PERMIT FOR NEW A/C
7) SECURE NM CABLE TO JUNCTION BOX
8) SERVICE IS ENERGIZED WITHOUT CLEARANCE