Permit: T07EL01262

Parcel: 115201730


Addresses:

1813 W LESTER ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
07/17/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
1) CALL FOR FINAL ONCE SWITCHED OVER
2) 205 NCE 250-104 B GIVES THE METHODS APPROVED FOR BONDING GAS LINES, 1 TO NEUTRAL OF SERVICE, 2 TO GROUND COMING UP FROM RODS, 3 TO RODS THEMSELVES, 4 OR WHERE EQUIPMENT GROUND FOR THE CIRCUIT WHICH MAY BE THE ONE TO ENERGIZE THE GAS PIPING-CAN BE USED AS BONDING JUMPER
3) YOU NEED TO USE ONE OF ABOVE SEE CODE SECTION
4) WILL CLEAR FOR SERVICE SWITCH OVER CALL FOR FINAL