Inspection History Details
Inspection Status: Partial Approval
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/04/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) RECALL AFTER SWING OVER COMPLETE |
|
| 08/13/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. INSTALL LISTED MAST BRACING. CANNOT USE SMASHED EMT AND MINERALLAC STRAPS - NEC 230.28 2. GROUND RODS TO BE MIN. 6' APART - NEC 250.53 & 250.56 3. INSTALL PROTECTIVE BUSHING AROUND SUB-PANEL FEED THROUGH BACK OF JUNCTION BOX AND SEAL OPENING WITH NON-COMBUSTIBLE MATERIAL -- NEC 300 4. CONNECT EQUIPMENT GROUNDING CONDUCTOR TO JUNCTION BOX AT RIGHT OF DOOR - NEC 250.148 5. INSTALL PROTECTIVE BUSHING AROUND BRANCH CIRCUIT CONDUCTORS AT JUNCTION BOX AT RIGHT OF BACK DOOR AND SEAL OPENING WITH NON-COMBUSTIBLE MATERIAL |