Permit: T07EL00538

Parcel: 140160130

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T07EL00538

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/05/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
04/04/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
OUTLET ON LEFT SIDE OF SUB-PANEL
NOT ON APPROVED PLAN -- NOT GFI PROTECTED
03/30/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. GROUNDS & NEUTRALS TO BE ISOLATED AT SUB-PANEL UNDER PORCH. 3-WIRE FEEDER AT SUB-PANEL ONLY 2 WIRES INTO PEDESTAL??
2. GROUND SYSTEM PROPERLY, INSTALL RACEWAY PER CODE
SUPPORT PER CODE, CHASE NIPPLE NOT ALLOWED FOR TERMINATION INTO PEDESTAL. TERMINATIONS FOR LOADS NOT TO BE RUN THRU UTILITY COMPARTMENT.
3. 36" OF WORKING CLEARANCE IN FRONT OF SUB-PANEL
COOLER J-BOX NOT SUPPORTED.