Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
Permit Number - T07EL00172
Inspection Description - ELECTRIC - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/23/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* NO ANSWER -- BUILDING LOCKED - NO MESSAGE |
|
02/21/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* INSTALL ALL RECEPTACLES, SWITCHES, LIGHT FIXTURES, ETC COMPLETE WORK, RECALL INSPECTION NO POWER CLEARANCE UNTIL DONE |
|
02/15/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* RIGO 551-0362' OK TO COVER WALLS |
|
02/13/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* LUGO'S WIRING IS CONTR. OK TO COVER IN KITCHEN STOREROOM OK EXCEPT RECEPT ON EAST WALL NOT WIRED PROPERLY UNIT #290 |
|
01/30/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ROMEX HAS TO BE SECURED NAILED WITHIN 2. GROUNDS IN BOXES NOT TO BE TWISTED 3. IMPROPERLY WIRED STORAGE ROOM TO SOUTH OF UNIT ATTACHED. 4. WIRING IN SERVICE PEDESTAL SHOWS EXPOSED WIRING INSIDE BOX CLOSE OPEN. 5. UNIT IS UNOCCUPIED - THIS REQUIRED A LICENSED ELECTRICAL CONTRACTOR TO DO WORK. 6. REPLACE BURNT WIRING TO FAN -- VERIFY FAN OK |