Permit: T07CM04729

Parcel: 141185300


Addresses:

9538 E OLD VAIL RD

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
04/08/2009 EXCAVATION/LAYOUT REBAR & ZON Approved
12/05/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
2 DOCK RECEIVING AREA CANOPY COLUMN FOOTINGS AND TWO TRUCK DOCK SUMP PITS OK
SPECIAL INSPECTION APPROVED
11/20/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
HORIZONTAL & VERTICAL REINFORCEMENT BARS FOR SOUTH TRUCK DOCK CONCRETE WALLS -- OK TO POUR AND EPOXY DOWELS @ PANELS #29 AND #10 @ FLOOR SLAB
CONFORMATECH HAS SPECIAL INSPECTED
11/13/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
FOOTINGS FOR EAST, NORTH, WEST TRUCK DOCK WALLS AND TRASH ENCLOSURE OK -- SPECIAL INSPECTED
10/31/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
TILT UP WALL PANELS #9, 21, 22, 23, 24, 25, 26, 27 & 29
REINFORCEMENT STEEL & EMBEDS SPECIAL INSPECTOR HAS ACCEPTED -- OK TO POUR
10/29/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELED
10/24/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
TILT UP WALL PANEL STEEL REINFORCEMENT ON
PANELS #15 THRU #20, #28 & #30 INCLUDING EMBEDS &
PICK POINTS
CONFORMA TECH APPROVED
10/23/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
10/14/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
TILT PANELS #1 THRU #6 -- OK BY SPECIAL INSPECTOR
WAITING ON LEDGER ANGLES TO BE DELIVERED
09/26/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. EXTERIOR WALL FOOTING @ GRID G.0/1.0 TO 6.0
AND 1.0/F.0 TO G.0
2. COLUMN FOOTINGS @ F.0/1.0 AND F.3/1.0 -- OK

SPECIAL INSPECTION ACCEPTED
09/16/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
SPREAD COLUMN FOOTINGS @ GRID LINES D.0/6.0, E.0/6.0
AND F.0/6.0 -- OK TO POUR AND EXTERIOR WALL CONTINUOUS FOOTING @ GRID 6.0/FROM C.5 TO F.8 - SPECIAL INSPECTOR HAS ACCEPTED
09/11/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
SPREAD COLUMN FOOTINGS @ GRID LINES D.0/3.0, D.0/4.0,
B.0/6.0 & C.0/6.0 AND CONTINUOUS WALL FOOTING @ GRID LINES A.0/4.0 TO 6.0 AND 6.0/A.0 TO C.1 - SPECIAL INSPECTOR HAS ACCEPTED
09/10/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
SPREAD COLUMN FOOTINGS @ GRID LINES 1.0/B.0, 1.0/E.0,
1.0/D.0, 1.0/C.0, 1.0/E.7 & 1.0/F.4 AND CONTINOUS WALL FOOTING @ GRID LINES 1.0/A.0 TO G.0 AND A.0/1.0 TO 4.0
SPECIAL INSPECTOR HAS ACCEPTED
09/09/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELED
09/08/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
COLUMN SPREAD FOOTING @ GRID LINES
F.0/4.0, E.0/4.0, F.5/4.5, E.7/4.5, C.0/4.0, B.0/4.0, F.6/6.0, E.7/6.0, F.5/7.3, F.5/8.8, F.0/7.7, E.0/7.7, C.0/7.7, B.0/7.7, E.7/7.5 AND E.7/8.9 -- OK TO POUR
SPECIAL INSPECTION COMPLETED
09/04/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
WEST RETAINING WALL/SITE WALL FOOTING -
SPECIAL INSPECTOR, CONFORMATECH HAS APPROVED
09/02/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
DRAIN CULVERT
OK TO PLACE CONCRETE WHEN CONFORMA-TECH VERIFIES COMPLETION OF STEEL
08/29/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
RAINED OUT
CONTRACTOR CANCELED
08/28/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
DRAINAGE RETAINING WALL FOOTING ALONG EAST EDGE OF PROPERTY 420 L.F - SPECIAL INSPECTION PERFORMED BY CONFORMATECH OK TO POUR