Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM04612

Parcel: 133369680

Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T07CM04612

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
10/10/2008 SITE - SEWER Approved IVRS - Inspection :*
04/17/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
4" SDR APPEARS TO HAVE UNIFORM SLOPE
PROVIDE VERIFICATION OF SLOPE
WATER TEST OK
MAKE CONNECTION AT BUILDING
PROVIDE FULL SIZE CLEANOUT AT UPPER END OF SEWER
RECALL FOR INSP.
VENT DN STREAM ON BACK WATER VALVE IS OK
NOTE PLASTIC PIPING MAY NOT BE EXPOSED TO SUNLIGHT
04/16/2008 SITE - SEWER Denied IVRS - Inspection :
See detailed listing on site.| 999*
CLEANOUTS TO BE NO MORE THAN 100' MAX. INCLUDING RISE TO FINISH GRADE DISTANCE APART.
04/14/2008 SITE - SEWER Denied IVRS - Inspection :
See detailed listing on site.| 999*
- SEVERAL LOCATIONS ARE FLAT AND SOME LOCATIONS HAVE LESS THAN .5%
- ALL CLEANOUTS SHALL BE INSTALLED IN THE CORRECT DIRECTION OF FLOW
- TRACER WIRE SHALL BE GRN PER STATE LAW
04/09/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
4" SDR FROM MAIN TO PROP. LINE INSTALLED AT LESS THAN 1% PROVIDE APPROVED PLAN REV. AND VERIFICATION OF GRADE.
04/03/2008 SITE - SEWER Denied IVRS - Inspection :
See detailed listing on site.| 999*
- NO TRACER WIRE INSTALLED
- CONNECTION TO CLAY SEWER MAIN IS 5' FROM MH
PLAN SPECS 10'
- CONNECTION IS AT 22 DEG. PC DETAIL 401 REQUIRES 45 DEG.
- PLAN SPECS 1% SLOPE ANYTHING LESS (.83%) WILL REQUIRE ENGINEER APPROVAL AND PLAN REVIEW ALSO, VERIFICATION OF GRADE
- C1.2 SPECIFIES A BACKWATER VALVE OP-1 DOES NOT
- UPC SEC. 904.1 REQUIRES EACH CONN TO A SEWER TO BE VENTED
- CONTACT PIMA COUNTY ABOUT SEWER TAP CONNECTION
ASK PC TO CONTACT BRIAN W/COT @ 820-6738 OR PROVIDE PAPERWORK.
04/01/2008 SITE - SEWER Not ready for Inspection IVRS - Inspection :*