Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/21/2009 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 06/06/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED BUBBLE COVERS ON OUTSIDE GFI RECEPTACLES 2) LOWER CLEANOUTS DOWN TO GRADE WITH APPROVED CAP 3) TPR LINE TO WATER HEATER NEEDS 90 DEGREE ELBOW AND TERMINATE 6" ABOVE GROUND 4) REMOVE FLOOD LIGHT FROM FRONT OF GARAGE 5) BEDROOM RECEPTACLES NEED TO BE ON ARC-FAULT CIRCUIT AND SMOKIES 6) NEED TO COMPLETE OUTSIDE HOSE BIB WITH SIDE 7) NEED TO COMPLETE ACCESS DOWN FOR BATH TUB 8) NEED TO SEAL AROUND TOILET 9) DOOR HARDWARE NOT PER CODE REMOVE ALL DEAD BOLT LATCHES |