Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/06/2009 | BUILDING PRE-SLAB | Approved | IVRS - Inspection :* | |
| 09/02/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* BOTTOM OF SOUTH STAIRWELL AND SOUTHWEST ENTRY POUR BACK |
|
| 08/14/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* POURED STAIRWELL LANDINGS |
|
| 08/13/2008 | BUILDING PRE-SLAB | Partial Approval | OK TO SOUTH STAIR LANDINGS 6X6 WW | |
| 08/12/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* 1. REMAINING 2ND FLOOR 2. PENTHOUSE FLOOR 3. TO BE SPECIAL INSPECTED 4. DESKS PUDDLE WELDED |
|
| 08/11/2008 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection :* | |
| 08/08/2008 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection :* CANCELED BY CONTRACTOR |
|
| 08/04/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* 1ST FLOOR POUR BACK EAST SIDE, NORTH SIDE INCLUDING SLAB AT BOTTOM OF STAIRS |
|
| 07/31/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* 2ND FLOOR DECK A TO E 11 TO 13 OK TO POUR |
|
| 07/30/2008 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection :* | |
| 07/29/2008 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection :* DETAILS S3.3 44 AND 43 A TO F - 11 TO 13 |
|
| 07/24/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* 8 COOLING TOWERS POURED SPECIAL INSPECTED WESTERN TECH. ON SITE |
|
| 07/23/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* 8 COOLING TOWER FOOTINGS 36/S3.3 |
|
| 07/15/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* POUR BACK INTERIOR WEST WALL OK TO POUR |
|
| 07/14/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* 2ND LIFT RIMS 231-232 OK TO GROUT |
|
| 07/10/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* 1ST LIFT RMS. 231 & 232 24 S3.2 OK TO GROUT |
|
| 06/24/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* SECOND FLOOR DECK POUR @ GRID LINES #7 TO 11 |
|
| 06/17/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* ALL COLUMNS INT & EXT DRY PACKED |
|
| 04/17/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* A TO F 7 TO 13 OK TO POUR REBAR IN PLACE WAREHOUSE |
|
| 04/10/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* PARTIAL 1-7 A TO G NEEDS SPECIAL ON EVIDENCE RM AND RECORDS RM REBAR |
|
| 03/17/2008 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection :* | |
| 03/14/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* NEEDS SPECIAL INSPECTION FOR REBAR FOOTINGS E 1 TO 3 1 A TO F A 1 TO 4 INCLUDING COLUMNS AT 3F, 2F, 1F, 1E, 1D, 2B, A3 PLEASE ADD 01005 |