Permit: T07CM03770

Parcel: 11713069E

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
09/29/2009 MECHANICAL - FINAL Approved IVRS - Inspection :*
09/17/2009 MECHANICAL - FINAL Partial Approval 1. COUNTERTOP SURFACE IS NON COMBUSTIBLE COMPOSIT.
2. DISTANCE TO LVOUP FROM FRONT OF COOKING SURFACE WITHIN 4'
09/16/2009 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
09/14/2009 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PER 507.1 IMC-ALL SURFACES WITHIN 18" OF COOKING SURFACE MUST BE NON COMBUSTIBLE. SUCH AS SHEETMETAL OR CERAMIC TILE
2) PER 507.12 O,C-THE INSIDE EDGE OF HOOD SHALL OVER HANG COOKING APPLIANCE BY A MIN. OF 6" ON ALL OPEN SIDES. THE VERTICAL DISTANCE BETWEEN THE FRONT LOWER LIP AND THE COOKING SURFACE SHALL NOT EXCEED 4'
3) PROVIDE COOKING APPLIANCE INSTALLATION INSTRUCTIONS
08/27/2009 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*