Permit: T07CM03770

Parcel: 11713069E

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/11/2009 FRAMING Approved IVRS - Inspection :*
1) 204A HARD LID
07/23/2009 FRAMING Partial Approval IVRS - Inspection :*
1) FRAMING SW ELEVATOR LOBBY
07/02/2009 FRAMING Partial Approval IVRS - Inspection :*
1) STAIRWELL A & E PARTIAL
06/29/2009 FRAMING Partial Approval IVRS - Inspection :*
1) STAIRWELL 'A' CHECKING ON SPIRAL STAIR CLEARANCE
06/26/2009 FRAMING Partial Approval IVRS - Inspection :*
1) 2ND FLOOR OK TO PROGRESS
06/24/2009 FRAMING Partial Approval IVRS - Inspection :*
VENT SHAFT OK
06/23/2009 FRAMING Not ready for Inspection IVRS - Inspection :*
CANCELED BY CONTRACTOR
06/22/2009 FRAMING Partial Approval IVRS - Inspection :*
SOFFIT DORM LOBBY 2ND FLOOR
06/16/2009 FRAMING Partial Approval IVRS - Inspection :*
DORM ROOM HARD LIDS
06/15/2009 FRAMING Partial Approval IVRS - Inspection :*
1. BELL TOWER EXCEPT HARD LID
2. BASEMENT 1ST AND 2ND FLOOR
06/11/2009 FRAMING Partial Approval IVRS - Inspection :*
2ND FLOOR DORM AREA - OK TO PROGRESS VENT
SHAFT 2HR WALL
06/09/2009 FRAMING Partial Approval IVRS - Inspection :*
109, 106 HARD LID, CONFERENCE ROOM
06/03/2009 FRAMING Partial Approval IVRS - Inspection :*
05/27/2009 FRAMING Partial Approval IVRS - Inspection :*
2ND FLOOR ROOMS #213-224
05/21/2009 FRAMING Partial Approval IVRS - Inspection :*
1) WORKING ON NORTH 1/2 2ND FLOOR CORRIDOR SOFFIT
05/18/2009 FRAMING Partial Approval IVRS - Inspection :*
WORKING ON DORM ROOMS -- OK TO PROGRESS
05/14/2009 FRAMING Partial Approval IVRS - Inspection :*
1) 2ND FLOOR SOUTH 1/2 CORRIDOR LID, 1ST FLOOR DOME HARD LID
05/08/2009 FRAMING Partial Approval IVRS - Inspection :*
REMAINING ATRIUM CEILING FRAMING
05/06/2009 FRAMING Partial Approval IVRS - Inspection :*
2ND FLOOR OK TO PROGRESS
05/01/2009 FRAMING Partial Approval IVRS - Inspection :*
OK TO PROGRESS
MAINTENANCE MINIMUM CLEARANCE FOR ACCESS PANELS
04/28/2009 FRAMING Partial Approval IVRS - Inspection :*
1. FITNESS RM. DROP CEILING FRAMING 1ST FLOOR
2. 2ND FLOOR OK TO PROGRESS SCREWS TO BE REMOVED FROM TOP TRACK
04/02/2009 FRAMING Partial Approval IVRS - Inspection :*
1. ATRIUM LID
2. RFI #385 LINTELS INSTALLED INCORRECTLY
04/01/2009 FRAMING Partial Approval IVRS - Inspection :*
1. ATRIUM UPPER FRAMING DETAILS 335, 334
2. UPPER SOFFITS N 2/3 BRACE AT 4' O.C.
03/13/2009 FRAMING Partial Approval IVRS - Inspection :*
EAST SIDE OF BIRD CAGE OK DENSGLASS
03/03/2009 FRAMING Partial Approval IVRS - Inspection :*
1. S, W, N SIDES OF BIRDCAGE
2. RAISED PLATFORM ON 1ST FLOOR
02/17/2009 FRAMING Partial Approval IVRS - Inspection :*
1ST FLOOR FROM LINE 8 EAST
01/09/2009 FRAMING Not ready for Inspection IVRS - Inspection :*
SLIP TRUCK NOT BEING USED