Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/03/2007 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 10/02/2007 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* TRAP PRIMER NOT PROPERLY CONNECTED AT DRAIN PIPING NOT PER PLAN - REDLINES NOT COMPLETE, UNAPPROVED REVISION IS NOT ACCURATE. |
|
| 09/28/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* HAVE REDLINES DRAWN IN ON APPROVED PLAN PRIOR TO PRE-SLAB INSPECTION. RECALL FOR INSP. BEFORE CONCRETE |
|
| 09/27/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* - TEST ON DWV OK - GT NOT INSTALLED PER PLAN. REDLINE CHANGES OF GW AND GT ORIENTATION - INSTALL CLEANOUTS REQUIRED. 135 DEG. MAX CHANGE OF DIRECTION - MAKE CONNECTION TO GT - CORRECT SLOPE ON 2" GW - RECALL FOR INSP PRIOR TO COVERING |
|
| 09/21/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* SOIL PIPE OK, 3" NOT PENETRATING FOOTING RECALL FOR CONTINUATION OF GW AND FOR FS AND FD INSTALLATION |
|
| 09/20/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) NOT INSTALLED PER PLAN-NO RED LINES ON SITE 2) WILL REQUIRE 3" DISCHARGE ON GREASE TRAP |