Permit: T07CM03275

Parcel: 124050620


Addresses:

922 E UNIVERSITY BL


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T07CM03275

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
01/11/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
01/10/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
A TRAP ARM MAY ONLY CHANGE DIRECTION 90 DEG.
WITHOUT AN ADDITIONAL CLEANOUT
THE CLEANOUT IS TO BE ON THE END OF THE
TRAP ARM (WYE BRANCH C.O) SEE DRAWING
01/09/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. EXCEPT IN THE CASE OF A WYE BRANCH OR END OF THE LINE CLEANOUT, CLEANOUTS SHALL BE INSTALLED ABOVE THE FLOW LINE OF THE PIPE: BESIDES, AT RELOCATED SINK BLAKE TEE IS LISTED TO BE INSTALLED VERTICALLY.
01/08/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
12/10/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
ALL CHANGES TO THE PLAN, MUST BE ACCOMPANIED BY REDLINES. REDLINES ARE TO BE COMPLETED AT TIME OF INSPECTION. SUPPORT RPPBP TO WALL.
11/14/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO ADDRESS
MISSING SUPPORTS
6X4 RESTRICTION ON ROOF DRAINS
CALL FOR RD INSP WHEN READY
11/13/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK TO COVER WALLS BEHIND TR. WILL NEED TO TRIM OUT BOTH CLEANOUTS BEHIND WCS
2) WILL NEED TO SEE CLOSET FLANGES AFTER FINISHED FLOOR
3) FLOOR MOUNTED LAV CARRIERS NOT YET INSTALLED
11/05/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. PLEASE POST YOUR ADDRESS
2. HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION
TO BE A SWEEP
3. SUPPORT ALL STUB OUTS
4. PLAN SAYS THAT WATER PIPING SHALL BE INSTALLED TO AVOID CONTACT WITH STRUCTURE TO PREVENT EXCESSIVE NOISE.
5. SUPPORT VERTICAL PIPE
SUPPORT HORIZONTAL PIPE
PLUMBERS TAPE NOT APPROVED STRAP
6. YOU MUST REDLINE ALL CHANGES TO THE PLAN
10/26/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CONTINUED "NOT READY" WILL RESULT IN A
REINSPECTION FEE
09/20/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) ABS DWV NOT INSTALLED PER PLAN
2) CONTRACTOR TO RED LINE AS BUILTS BEFORE COVERING
3) WATER TEST ON RISER TO TEN FEET