Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/28/2009 | BUILDING - FINAL | Approved | IVRS - Inspection :* 1) CERTS FAXED TO OFFICE |
|
| 05/27/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RAISE DISHWASHER DRAIN TO COUNTER BOTTOM 2) LOOSE OUTLET NORTH OF STOVE 3) A/C UNIT NEEDS SECONDARY CONDENSATE DRAIN OR A CUT OFF SWITCH 4) MASTER CLOSET LIGHT MUST HAVE COVER-NO EXPOSED BULBS IN CLOSETS |
|
| 09/17/2008 | BUILDING - FINAL | Not ready for Inspection | VENT ALONG EAST WALL AT RAFTERS IS NOT ALLOWED FOR BUILDING ON PROPERTY LINE. 1 HOUR CONSTRUCTION REQUIRED WITH NO OPENINGS AND NO PROJECTIONS. ROOF DETAIL WITH 1" GAP IS INCORRECT! |