Permit: T07CM02468

Parcel: 13734001C


Addresses:

1660 W VALENCIA RD


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T07CM02468

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
04/11/2008 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
OK TO GROUT
WEST LOADING RAMP - SPECIAL INSPECTED
04/10/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
OK TO GROUT EAST LOADING DOCK & TRASH ENCLOSURE
SPECIAL INSPECTED
12/07/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12/06/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
PARTIAL CONTINGENT UPON LEERAY APPROVAL TO GO 2-LIFTS WITH CLEANOUTS
12/05/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12' OK WHEN SP. INSP. CONFIRMS VERTICAL STEEL PLACEMENT D2(1-3)
12/04/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH BLDG, LINE D/1 TO D/2 GROUTED
NEW PLAN DATED 11/27/07 APPROVED WILDAN
11/30/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ALL TOPPED 2-10 ONLY NW AREA 1-1.5 REMAINS
11/29/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
16' TO 20' 13 F5-5 J-10-13 F5-10-13 TOP OUT
11/28/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
13-F5-J 12' TO 16'
J-10-13
11/28/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection F5-10-13
11/27/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 12' E 7 A; 16'S
11/26/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
8' LIFT OK
11/20/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NW CORNER PER SPECIAL INSP. CONFIRMATION
11/19/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINE 1/D-F @ 20'
11/16/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP 4.5-7 NORTH WALL; 20' LINE 1; TOP N. WALL 7-10
11/15/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINE A.5/9-10 @ 12'; LINE 1/D-F & LINE D 3-5 & LINE 3 D-D.2 @ 8'
11/14/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINE B/9-10 @ 8'
LINE D/3-5 @ 4'
LINE 1/D-F (@4')
OK TO GROUT PROGRESS AREAS
11/13/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) BLDG 2A-CAISSONS AT LINES F5/12.8, F5/13, J/12.8, J/13-(9'-6" X 2'-6")-OK TO POUR
11/09/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BUILDING #3 C/5.9 20'8"-25'4"
5/C-A 20'8" - 25'4"
R/8.5-9 4'-12'
9/A-R 4'-12'
1/G.5-H 14'-18'
J/1-3' 14'-18'
11/08/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
20' 5-7/C; 28' J/5-7; 16' J/1-3 & G-1/1
11/07/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
A/8-14 @ 8'
C/D-47 @ 16'
J/3-7 @ 23'4"
11/06/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
N - 12' @ LINE C/5-7
W - 8' @ LINE 1/G-H
19' @ LINE J/3-7
11/05/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. LINE B/A-8/10 @ 4'8" OK
2. LINE C/D-4/7 @ 8'8"
LINE J @ 14'8" FROM 3/7
LINE 1- K/J @ 4'
11/02/2007 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999*
STIRRUPS UPSIDE DOWN
11/01/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINE J/1-7 @ 8'; STEM WALL LINES B/8.5-9; 9/A-B, A/9-9.5
GROUTED - SPECIAL INSPECTION
10/30/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP J/7-10; TOP 10; TOP 7; 16' B/7-8
10/29/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. 12' LINE B
25' LINE 10, & J; 28' J/8-9
10/26/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. LINE J 25'8"
2. LINES 7 & 10 FROM D1-J @ TOP
10/25/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/24/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINE J & 7 TO 20'
10/23/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINE 10, LINE J TO 20'
10/19/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
16' LINE 10'
16' LINE 7/G-J
12' LINE 7/B-G
12' LINE J
4' LINE B/7-10
10/18/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
8' @ J-B/7-10 EXCEPT LOAD DOCK
10/16/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
4' 7-10/J-B (EXCEPT LOAD DOCK AREA)
10/15/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
STEM WALLS