Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2010 | BUILDING - FINAL | Approved | ||
| 07/07/2009 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) MUST REMOVE SIGNS AT FENCE, BANNERS AND A FRAME |
|
| 04/25/2009 | BUILDING - FINAL | Partial Approval | OK TCO | |
| 04/24/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. INCORRECT GUARDS @ STAIRS 2. INCORRECT HANDRAILS @ STAIRS 3. TOILETS MUST BE ACCESSIBLE TYPE 4. GRAB BARS REQUIRED IN RESTROOMS 5. DOOR HARDWARE MUST UNLOCK FROM EGRESS SIDE WHEN HANDLE TURNED (BOTH BATH AND RECORDING) 6. FLUSH HANDLES MUST BE ON WIDE SIDE OF ROOM 7. SIGN OVER ENTRANCE "THIS DOOR MUST REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED" |
|
| 04/16/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SEAL EXTERIOR PENETRATIONS 2. INSTALL ACCESSIBLE PARKING SIGNS 3. PROVIDE ACCESS AND APPROVED PLANS 4. GUARD & HANDRAIL REQUIRED @ STAIRS 5. HANDRAIL EXTENSIONS REQUIRED PER IBC 1012 6. FINISH ALL WORK 7. PROVIDE FINALS FROM ALL TRADES |