| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/09/2007 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
| 07/06/2007 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED SWEEPING DRAINAGE FITTING AT 3" TO 2"-NO SANTEE 2) NEED TO LEVEL/PLUMB P-TRAP FOR SHOWER 3) INSTALL PLUMB WRAP FOR PRE-SLAB 4) CLEANOUT FOOTINGS AND MAINTAIN 3" STEEL TO SOIL SEPERATIONS 5) SLOPE ALL DRAINAGE 1/4" PER FOOT |
|
| 06/27/2007 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HORIZONTALS IN FITTING SHALL NOT BE TIED TO VERTICALS EMBEDED IN GROUND 2) ALL PLUMBING SUB STANDARD P.S. GET PLUMBER TO HELP 3) UFER GROUND SHALL BE TIED TO 20' CONTINOUS IN FTG |