Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07CM01232

Parcel: 138191880


Addresses:

394 W ELVIRA RD

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
07/09/2007 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
07/06/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED SWEEPING DRAINAGE FITTING AT 3" TO 2"-NO SANTEE
2) NEED TO LEVEL/PLUMB P-TRAP FOR SHOWER
3) INSTALL PLUMB WRAP FOR PRE-SLAB
4) CLEANOUT FOOTINGS AND MAINTAIN 3" STEEL TO SOIL SEPERATIONS
5) SLOPE ALL DRAINAGE 1/4" PER FOOT
06/27/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HORIZONTALS IN FITTING SHALL NOT BE TIED TO VERTICALS EMBEDED IN GROUND
2) ALL PLUMBING SUB STANDARD P.S. GET PLUMBER TO HELP
3) UFER GROUND SHALL BE TIED TO 20' CONTINOUS IN FTG