Permit: T07CM01151

Parcel: 14042080C

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
12/19/2008 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
PERGOLA FOOTING PER SKA 4 COLUMNS
11/12/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO POUR GRATED TRENCH
11/10/2008 EXCAVATION/LAYOUT REBAR & ZON Cancelled IVRS - RI canceled
09/22/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
CANCELED BY CONTRACTOR
09/19/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
DUMPSTER ENCLOSURE F C1.2
09/18/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
DUMPSTER PAD NR

1. USED #4 FOR VERTS
AND #3 MATT
09/05/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
PEDESTALS AS MARKED ON PLAN
08/22/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. 9 EXT. COLUMN FOOTINGS AND PEDESTALS AS
MARKED ON 1/2 SET
2. PATIO FOOTING AS MARKED ON 1/2 SET
3. SPECIAL INSPECTION KRAZAN
08/21/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
REMAINING LIGHT CAISSONS AS MARKED ON 1/2 SET
08/20/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
LIGHT POLE CAISSONS AS MARKED ON 1/2 SET
SPECIAL INSPECTED KRAZEN
08/18/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
REMAINING BLDG. FOOTINGS AND 4 LIGHT POLE CAISSONS
AS MARKED ON 1/2 SET
08/15/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
2 LIGHT POLE BASES ON NORTH SIDE -
FIRST TWO WEST TO EAST
08/14/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
PARTIAL 8/S3.1, 19/S3.1
MAINTAIN DIRT TO REBAR CLEARANCES

*KRAZEN SPECIAL INSPECTED
08/13/2008 EXCAVATION/LAYOUT REBAR & ZON Cancelled
08/12/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. MAINTAIN REBAR CLEARANCE
2. CLEAR FOOTINGS OF DEBRIS AND LOOSE DIRT
3. OK TO PROGRESS
08/11/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
CANCELED BY CONTRACTOR
08/05/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
WATERPROOF MEMBRANE INSTALLED ON ELEVATOR SHAFT

1. PROVIDE CITY APPROVAL FOR SPECIAL INSPECTION COMPANY BEING USED
07/29/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
ELEVATOR PIT S3.1 DETAIL #1 OK TO POUR
FLOOR & WALLS MONO POUR INSTEAD OF SLAB AND STEM WALL

1. COMPACTION TEST BY KRAZAN THEY WILL BE TESTING CONCRETE ALSO