Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 04090 -- APPROVED PERMIT #T07ME00006 NOTE: PERMANENT CAP OLD GAS PIPING IN FURNACE CLOSET |
|
| 12/29/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) I'M SORRY I DIDN'T GET YOUR MESSAGE YESTERDAY; I WAS HAVING PHONE PROBLEMS AND DIDN'T HEAR IT UNTIL THIS MORNING 2) GAS PIPE REQUIRES A MINIMUM OF 12" OF COVER AT ALL POINTS 3) FIELD WRAPPING IS REQUIRED WHERE PIPING HAS BEEN STRIPPED FOR THREADING OR MARRED BY WRNCHES, ALL WRENCH MARKS ARE TO BE TAPED 4) ALL FIXED APPIANCES ARE TO HAVE A SEDIMENT TRAP 5) PROVIDE INSPECTION HISTORY FOR NEW FARNESS 6) T & P RELIEF DRAIN TO BE GRAVITY TYPE 7) BOND REQUIRED BETWEEN GAS AND METALLIC WATER PIPING |
|
| 12/28/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* NOBODY HOME |