Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06PL01541
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/01/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
08/31/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* CALLED AND SAID NR |
|
08/28/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ONE HOME 850 AM 1. PROVIDE AN AIR PRESSURE TEST ON ALL GAS PIPING. 2. REPAIR FLOOR SUPPORTING WATER HEATER. 3. INSTALL A DRAIN PAN UNDER WATER HEATER TO PREVENT DAMAGE TO SUBFLOOR. 4. PROVIDE COMBUSTION AIR OPENINGS AT WH 5. ACCESS TO ALL GAS APPLIANCES IS NECESSARY |