Inspection History: PLUMBING - FINAL
Permit Number - T06PL00758
Inspection Description - PLUMBING - FINAL
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/24/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. UNABLE TO DO INSPECTION -- GATE LOCKED NO ONE HOME. |
|
05/17/2006 | PLUMBING - FINAL | Denied | 1. ABOVE GROUND HORIZONTAL GAS PIPING SHALL BE KEPT 3 1/2" MIN. ABOVE GRADE AND PROPERLY SUPPORTED W/PIPE SUPPORTS EVERY 8 FEET. 2. PROVIDE AN AIR PRESSURE TEST ON GAS SYSTEM USING A 15 PSI GAUGE. 3. PROVIDE AN OPERATING TEMPERATURE & PRESSURE RELIEF VALVE ON WATER HEATER. 4. TERMINATE T&P 6"-24" ABOVE GROUND W/OUT THREADS, USE APPROVED MATERIALS. 5. SECURE VENT W/SHEETMETAL SCREWS. |
|
05/09/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ANSWER AT FRONT DOOR 8:21-8:27 AM NO GAUGE AT METER. PRESSURE TEST REQUIRED. ACCESS TO GAS APPLIANCES REQUIRED. |