Inspection History: ELECTRIC - FINAL

Permit Number - T06OT00154

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/01/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
OK C OF O
04/27/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
STILL HAVE OPEN WIRING IN SEVERAL LOCATIONS - AT EXTERIOR FRONT, IN CEILING, J-BOXES, PANELS (OPEN BREAKER SPACES), ALSO EXTERIOR PANEL NEED SCREW TO HOLD INNER COVER ON AND CORRECT BREAKERS INSTALLED. OLD INTERIOR PANEL USED AS J-BOX NEEDS TO HAVE COVER SCREWED CLOSED.
04/21/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
8:15 DOOR LOCKED - MESSAGE LEFT
1:45 PM - 2ND TRIP
1. NEED A LICENSED ELECTRICAL CONTRACTOR TO GO THROUGH PROPERTY AND MAKE NEEDED REPAIRS. HE NEEDS TO TAKE OUT A 1 HOUR REPAIR PERMIT.
2. HAVE OPEN WIRING IN CEILING.
3. HAVE ROMEX IN CEILING.
4. NEED BLANKS FOR OPEN BREAKER SPACES IN ALL PANELS
5. HAVE SHORT IN EXTERIOR PANEL BRANCH CKT.
6. CHECK GROUNDING AND FEEDERS @ SERVICE.
7. IDENTIFY ALL EQUIPMENT.
8. CHECK ROOF EQUIPMENT & WIRING.