Inspection Status: Denied
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2006 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. GAS LINE NOT HOLDING PRESSURE. 2. SECURE GAS LINE TO WALL. 3. CONDENSATE MUST TERMINATE WITHIN 6" OF THE GROUND WITH AN ELBOW & A NIPPLE TO DIVERT WATER AWAY FROM HOUSE. |
|
| 12/04/2006 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - LOW VOLTAGE WIRE MUST BE IN CONDUIT - BLOCK & CLAMP EXPOSED PVC EVERY 4' & PAINT WITH LATEX PAINT. PROVIDE A TRAP. - SUPPORT ELEC. CONDUITS EVERY 8' - YOU MUST USE A FUSED DISCONNECT FOR THIS UNIT. UNIT #2 - VENT MUST BE DOWNSTREAM OF TRAP. CONDENSATE CANNOT TERMINATE INTO A SEWER VENT BLOCK & CLAMP PVC & PAINT SAME ELEC. REQUIREMENTS AS UNIT #1 PROVIDE GAS PRESSURE TEST. SEAL ROOF JACK. |