Inspection Status: Violation
Inspection History: VIOL - MEANS OF EGRESS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/27/2006 | VIOL - MEANS OF EGRESS | Violation | IFC 2003 1008.18 Door operation No double key dead-bolt locks, no special knowledge needed, no slide bolt locks. 1. REMOVE DOUBLD KEYED DEAD BOLT FROM WEST BEDROOM AND DISABLE THROW IN SECOND THUMB LATCH DEAD BOLT ON POOL DOOR AND FRONT EXIT. |
|
| 12/27/2006 | VIOL - MEANS OF EGRESS | Violation | IFC 2003 1027.2 Maintenance of egress components. 1. DOOR LEADING TO BACK YARD FROM E BATHROOM IS NOT AN EXIT , BUT A POOL DOOR. |
|
| 12/27/2006 | VIOL - MEANS OF EGRESS | Violation | IFC 2003 1027.3 Egress pathway clear All path ways to all exits required or not. This includes exits from windows. 1. MOVE BED IN BEDROOM # 3 AWAY FROM WINDOW. |
|
| 12/27/2006 | VIOL - MEANS OF EGRESS | Violation | IFC 2003 1027.2 Must be able to use easily and reliable Check if they open and look at security devices. 1. REPAIR WINDOWS THAT DO NOT OPEN IN BEDROOMS 1 & 3 |
|
| 12/27/2006 | VIOL - MEANS OF EGRESS | Violation | IFC 2003 1026.5 Emergecy ligting. EMERGENCY LIGHTING MUST BE HARD WIRE TO THE HOMES POWWER SOURCE. |
|
| 12/27/2006 | VIOL - MEANS OF EGRESS | Approved |