Case: T06FR02919

Parcel: 127070450


Addresses:

5120 E ALBERTA DR

Inspection Status: Violation

Inspection History: VIOL - BUILDING SVCS & SYSTEMS

Date Description Inspector Results Comments
12/27/2006 VIOL - BUILDING SVCS & SYSTEMS Violation IFC 2003 605.5 Extension cords
Grounds, used as permanent wiring, run under carpet, attached to walls can be replaced w/ power strip that has overcurrent protection
1. SURGED POWER TAP IS DAMAGED, REMOVE AND REPLACE WITH NEW POWER TAP.
12/27/2006 VIOL - BUILDING SVCS & SYSTEMS Violation IFC 2003 604.4 Fuel type portable heater ( prohibited )
Electrical heaters should have a tip switch.
1. PORTABLE HEATERS SHOULD HAVE A TIP SHUT-OFF
12/27/2006 VIOL - BUILDING SVCS & SYSTEMS Approved
12/21/2006 VIOL - BUILDING SVCS & SYSTEMS Violation TFB AG105.2 Pools and spas protected
5’ high fence, self closing gate that is hinged away from the fence. No laddering outside the fence. Gate must be locked if not in use.
OBJECT NEXT TO FENCE CREATE ACCESS TO THE POOL.
1. REMOVE LOCKED BIKES FROM FENCE.
2. TRIM TREES SO THEY WILL NOT BE USE TO CLIMB OVER FENCE.
3. PLACE HEAVEY WIRE OVER FENCE WHERE THE BRICK BBQ CAN BE USED TO CLIMB OVER FENCE
12/21/2006 VIOL - BUILDING SVCS & SYSTEMS Violation IFC 2003 605.1 Abatement of electrical hazards
Exposed electrical wires , covers, and panels locked.
Undergroud romex can be above 7’ and not in conduit, if protected from UV light and damage.
1. ELECTRICAL WIRE ON E SIDE OF BUILDING MUST BE PLACE IN CONDUTE AND A BOX PLACE AT THE POINT IT COMES OUT OF WALL, OR REMOVED.
2. PLACE LARGE ELECTRICAL WIRE NEAR PANNELS ON BACK OF BUILDING IN CONDUTE.