Inspection Status: Approved

Inspection History: VIOL - BUILDING SVCS & SYSTEMS

Date Description Inspector Results Comments
02/02/2007 VIOL - BUILDING SVCS & SYSTEMS Approved
11/30/2006 VIOL - BUILDING SVCS & SYSTEMS Violation 20. TFC 605.5 Extension cords
Grounds, used as permanent wiring, run under carpet, attached to walls can be replaced w/ power strip that has overcurrent protection

1. iMPROPER USE OF POWER TAPS IN NW BEDROOM UNDER BED AND AC UNIT
11/30/2006 VIOL - BUILDING SVCS & SYSTEMS Violation 21.TFC 605.4 Multi-plugs and power-taps
UL listed,No end to end, home made
1. MULIT-PLUG ADAPTER MUST HAVE A TRIP BUTTOM
11/30/2006 VIOL - BUILDING SVCS & SYSTEMS Violation 23.TFC 603.1 & 316.2 Fuel fired appliances and house cleaning.
Furnaces, dryer and hot water heaters are all heat sources and must be maintained and cleaned.

1.RETAP VENT PIPE JOINTS
11/28/2006 VIOL - BUILDING SVCS & SYSTEMS Violation 6. TFC 605.1 Abatement of electrical hazards
Exposed electrical wires , covers, and panels locked.
Undergroud romex can be above 7’ and not in conduit, if protected from UV light and damage.

1. ELECRTICAL WIRE IN CLOSET OF SE BEDROOM MUST BE PLACED IN CONDUTE.

2. NEED OUTLET COVER ON W WALL IN SE BEDROOM.

3. ELECRITCAL WIRE TO LIGHT ON BACK PORCH NEED TO BE IN CONDUTE TO CEILING