Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
Case Number - T06FR02516
Inspection Description - INSP - FULL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/07/2007 | INSP - FULL | Approved | ABATED | |
12/11/2006 | INSP - FULL | Correction Required | FIRE INSPECTION REPORT for 7960-7980 S. Kolb MER Corporation ATTN: Kevin Loutfy 7960 S. Kolb Tucson AZ..85706 Mr. Loufty The Tucson Fire Department has conducted a fire safety inspection at the above stated business. Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2003 International Fire Code with modifications. Violations: 7960 S. Kolb Hazardous Communications 3305.2.1 Hazardous Materials Management Plans and Inventory Statements required. Detailed Hazardous Materials Management Plans (HMMP) and Hazardous Materials Inventory Statements (HMIS) complying with the requirements of Section 407 shall be prepared and submitted to the local emergency planning committee, the fire code official, and the local fire department. Corridors 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. · North Corridor Exit signs shall be illuminated at all times including the operation of the sign by battery back-up. · Southwest corridor shall have the exit signs illuminated Battery Lab 1: 1. 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. · Replace missing ceiling tiles throughout the business 2. 3003.3 Compressed gas cylinders shall be secured against accidental dislodgment. 3. 605.5 Do not use extension cord as a substitute for permanent wiring · Refrigerator Battery Lab #2: 1. 3003.3 Compressed gas cylinders shall be secured against accidental dislodgment: 2. 703.1 Maintain fire resistive construction: replace missing ceiling tiles on the South wall Room # 210: 605.5 Do not use extension cord as a substitute for permanent wiring. Casting Room: 1. 703.1 Maintain fire resistive construction-replace missing ceiling tiles. 2. 315.2 Maintain better housekeeping practices · This room shall be better organized. · The kilns shall be installed and maintained in accordance with the building code. Electrical Room: 1. 605.5 Do not use extension cords as a substitute for permanent wiring. 2. 1006.1 Emergency lighting shall operate 3. 605.3 Place blanks in the electrical panel where the breakers are missing 7960 Boiler Room: 1. 605.5 Do not use extension cords as a substitute for permanent wiring 2. 407 Properly label all containers outside the boiler room Office 115A: 605.5 Do not use extension cords as a substitute for permanent wiring Office 106: 3003.3 Compressed gas cylinders shall be secured against accidental dislodgment · 2 each Office G104 703.1 Maintain Fire Resistive construction · Replace missing ceiling tiles Office 119A 605.5 Do not use extension cords as a substitute for permanent wiring P.T.A. 605.5 Do not use extension cords as a substitute for permanent wiring · PTA Machine Flammable Liquids Storage Room 407.2 MSDS · The MSDS outside this room are weathered and hard to manage. Provide weather protection for the MSDS and arrange in an orderly manner. Carbon Foam Room: 1. 703.1 Maintain fire resistive construction- · replace missing or damaged ceiling tiles 2. 605.5 Do not use extension cords as a substitute for permanent wiring · Currently there is a cord that extends through the roof 3. 3003.3 Compressed gas cylinders shall be secured against accidental dislodgment 4. 704.1 Floor openings shall be adequately protected · Currently there is an opening in this room which has a board over it. This is not substantial enough to prevent falling into it.; Office P314 605.5 Do not use extension cords as a substitute for permanent wiring 2703.1.1 Chemical storage shall not exceed Maximum Allowable Quantities and shall be properly separated from incompatibles. TEM Room 703.1 Maintain Fire Resistive construction--Replace missing ceiling tiles 7980 S. Kolb 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: · Exit access corridors, passageways and aisles in rooms and spaces which require two or more means of egress. · Exit access corridors and exit stairways located in buildings required to have two or more exits. MMIC 605.5 Do not use extension cords as a substitute for permanent wiring Room #9 3003.3 Compressed gas cylinders shall be secured against accidental dislodgment Room #8 Ceramic Lab 703.1 Maintain Fire Resistive construction--Replace missing ceiling tiles Room #6 703.1 Maintain Fire Resistive construction--Replace missing ceiling tiles Room #4 1. 3003.3 Compressed gas cylinders shall be secured against accidental dislodgment 2. 901.6 Fire Extinguisher shall be serviced annually 3. 605.5 Do not use extension cords as a substitute for permanent wiring North Corridor 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. · North Corridor Exit signs shall be illuminated at all times including the operation of the sign by battery back-up. South Corridor 1027.2 Reliability. Required exit accesses, exits or exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency. Security devices affecting means of egress shall be subject to approval of the fire code official. 1027.3 Obstructions. A means of egress shall be free from obstructions that would prevent its use, including the accumulation of snow and ice. · Maintain exits free from obstructions-currently there is stock blocking exits (West) Carbon/Carbon Rollout Room 1. 901.6 Do not hang anything from the sprinkler piping 2. 605.5 Do not use extension cords as a substitute for permanent wiring · Crane Room #20 1. 605.5 Do not use extension cords as a substitute for permanent wiring 2. 407.1 Provide a sign on the Door indicating contents of the room Room #19 1. 3405.3.6.2 Listed and approved machines. Parts cleaning and degreasing conducted in listed and approved machines in accordance with Section 3405.3.6.1 shall be in accordance with Sections 3405.3.6.2.1 through 3405.3.6.2.7. · Proved a solder link for your parts cleaner 2. 605.5 Do not use extension cords as a substitute for permanent wiring Room #18 315.2 Storage in buildings. · Storage of combustible materials in buildings shall be orderly…. Room #15 1. 315.2.1 Ceiling clearance. · A minimum of 18 inches (457 mm) below sprinkler head deflectors in sprinklered areas of buildings. 2. 315.2 Storage of combustible materials in buildings shall be orderly…. · Maintain 24 inches of aisle width Room #14 1. 315.3 Storage of combustible materials in buildings shall be orderly…. 2. 605.5 Do not use extension cords as a substitute for permanent wiring · Currently there are three extension cord in this room that must be removed Modular Unit 1. 105.6.25 Industrial ovens. An operational permit is required for operation of industrial ovens regulated by Chapter 21. · You are hereby ordered to obtain a permit to utilize you modular unit to conduct the operation of the furnace/oven you have in the building. 2. 605.5 Do not use extension cords as a substitute for permanent wiring The Tucson Fire Department is committed to the protection of your property. Your help as a business owner and as a citizen is greatly appreciated. __________________________________________________ Property owner or Property Representative Signature _________________________________ Abatement Date __________________________ Captain Signature Sincerely, Jimmy R. Davis, Jr. Fire Inspector Tucson Fire Department 797 E. Ajo Tucson, AZ 85713-5011 (520) 791-4502 fire prevention center |