Permit: T06EL02395

Parcel: 124170840


Addresses:

1036 S FREMONT AV

Inspection Status: Approved

Inspection History: ELECTRIC - UNDERGROUND

Date Description Inspector Results Comments
01/19/2007 ELECTRIC - UNDERGROUND Approved IVRS - Inspection :*
01/11/2007 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
VERIFY SECOND GROUND ROD
EXPOSE FOR INSPECTION
12/22/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1. 2-GROUND RODS REQUIRED 6' MIN. APART
2. VERIFY WATER & GAS BONDING
3. SUPPORT RISER CONDUIT BELOW ROOF LINE
4. SUPPORT BOX TO WALL & INSTALL BUBBLE TYPE COVER FOR GFI RECEPT UNDER PANEL.
5. ALL CIRCUIT BREAKERS MUST BE SAME BRAND AS PANEL.
6. OUTSIDE J-BOXES MUST BE OUTDOOR RATED
7. GROUND WIRE REQUIRED IN FLEX CONDUIT. ALSO, INSTALL A SEALING LOCKNUT AT PANEL PENETRATION.
8. SUPPORT 1/2" CONDUIT & FLEX
9. RISER SUPPORT ON ROOF MUST BE LISTED, HOMEMADE NOT APPROVED.