Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T06EL00134
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/16/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
02/15/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE NOTES -- DO NOT CALL FOR INSP. UNTIL WORK DONE CORRECTLY USE QUALIFIED ELECTRICIAN |
|
02/14/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245*WHAT HAPPENED TO THE GROUND WIRES? THEY WHERE TWISTED TOGETHER IN THE J-BOX SEE NOTES LAST INSPECTION |
|
02/08/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245*INSTALL BUSHING OR CLAMPS TO PROTECT WIRING ( ROMEX) ENTERING J-BOX IN PORCH. USE WIRE NUT O CONNECT GROUND WIRE TOGETHER. GROUND J-BOX & LABEL ( J-BOX) |
|
01/27/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CHANGE TO SERVICE UPGRADE PERMIT-NEW SERVICE 2) EXPOSE GROUND RODS-2 REQUIRED 6' MINIMUM APART 3) #14 WIRE TO BE ON 15 AMP BREAKERS 4) ID THE NEUTRAL WIRE WHITE 5) EXPOSED ROMEX IN PORCH SHOULD BE IN RACEWAY |