Case: T06DV00590

Parcel: 12906262A


Addresses:

2943 E BEVERLY DR

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
02/20/2007 INSP - INITIAL CODE ENFORCMENT Approved SEE SIRE TO VIEW INITIAL INSPECTION NOTES DATES 02-20-07. - Mel
06/09/2006 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE ON INITIAL INSP. MET WITH INSP. R. DIAZ, CHIEF CORDINATOR DEBBIE, AND IN HOSE MANAGER BRIAN. COMPLAINT STATED PROBLEMS WITH COOLING. WALKED INTERIOR AND EXTERIOR OF STRUCTURE TO CHECK FOR MIN- HOUSING VIOLATIONS AND ZONING VIOLATIONS - FINDINGS ARE AS FOLLOWS.
FIRE SAFETY
SMOKE DETECTORS WERE PRESENT AND FOUND TO BE WORKING, NO EGRESS ISSUE WERE PRESENT.
ELECTRICAL
ELECTRICAL SYSTEMS WERE CHECKED
1) COVER PLATE MISSING IN EASTSIDE MDDLE ROOM. TEST EQUIPTMENT WAS USED ON RECEPTACLES AND ALL TESTED OUT GOOD. GFCI WAS TESTED AND WORKING IN BATH ROOMS.
2) CHECKED SERVICE DISCONNECT FOUND 1-15 AMP CIRCUIT CONNECTION LOOSE AT BREAKER.
3) EXTERIOR LIGHT FIXTURE BY SLIDING GLASS DOOR WAS FOUND LOOSE.
4) AC WALL UNITS IN CONVERTED CARPORT AND 2ND STRUCTURE IN BACK ARE NOT ON REQUIRED SEPERATE CIRCUITS. EXISTING SERVICE IS 125 AND APPEARS TO BE MAXED OUT. 2ND STRUCTURE IS USED AS HABITABLE SPACE PLUMBING
CHECK FOR PERMIT - NO PLUMBING ONLY ELECTRICAL. 1/2 PVC PIPING FROM ABANDONED WATER SOFTNER RUNS ALONG CONVERTED CARPORT WALL AND IS BROKEN AND NOT SECURED TO WALL.
MECHNICAL
EXHAUST MOTOR WAS CHECKED AND FOUND TO BE WORKING.
HEATING AND COOLING
1) CHECKED FURNACE CLOSET, LARGE AMOUNTS OF DUST AND COMBUSTIBLE LINT PRESENT THROUGH OUT CLOSET. HOT WATER HEATER AND FURNACE
2) FURNACE WAS FOUND WITH ILLEGALLLY INSTALLED FLEX PIPING IN SIDE FURNACE CONNECTED TO GAS VALVE.
INTERIOR FEATURES
KITCHEN CABINETS DRAWERS AND DOORS HAVE NOT BEEN MAINTAINED, SEVERAL DOORS AND DRAWERS WERE FOUND MISSING DRAWER FACES AND LOOSE AT HINGES.
WEATHER PROOFING
CONVERTED CARPORT ENTRY DOOR LACKING WATHER STRIPPING ECIDENCED BY LARGE AMOUNTS OF LIGHT SHINNING THROUGH AT TOP AND BOTTOM
W/O/P
APPEARS CARPORT HAS BEEN CONVERTED TO LIVING SPACE DNR INSPECTOR HAD STAFF CHECK FOR PERMIT NO WERE FOUND. WILL CHECK RECORDS AT D.S.D. RECORDS SEC. ALSO PATIO/PORCH HAS BEEN ATTACHED TO MAIN STRUCTURE IN A HAZARDOUS MANNER. 2X6 BEAMS HAVE BEEN SPLCED TOGETHER AT NORTH SIDE OF MAIN STRUCTURE WITH OUT PROPER ATTACHING HARDWARE. PICTURES WERE TAKEN.
COOLER
MASTER COOL COOLER LACKS SERVICE, PADS WERE FOUND WITH LARGE ABOUTS OF SEDIMENT, TOP 4" OF PAD ARE NOT WET, INDICATING WATER DISTRABUTION PIPE IS CLOGED AND REQUIRES SERVICING. ALSO ELECTRICAL CORD SHEETING IS CRACKED AND EXPOSING ELECTRICAL CONDUCTOR.
NOT FOR W/O/P : 2"X6" PORCH BEAMS ARE RESTING ON STRUCTURES ROOF.