Case: T06DV00590
Case Details
Entered Date:
06/05/2006
Applicant:
CHEN FUTAI & ZHANG GUIHUA JT/RS
Description:
SWAMP COOLER BLOWS AIR IN BEDROOMS, WALL MOUNTED A/C TO COOL KITCHEN AND LIVING ROOM. A/C UNIT NOT FUNCTIONING BECOMES VERY HOT DURING THE DAY. HAS 11 PEOPLE IN HOUSE, HAS A DISPUTE TO SIGN THE LEASE BEFORE THE AIR-CONDITIONING IS FIXED. CALLER STATES LANDLORD WILL NOT ADDRESS UNLESS A CITY OFFICIAL TELLS HIM TO ADDRESS. ONE PERSON 72 YEARS OLD ONE PERSON LATE 60'S MIDDLE AGED MENTALLY ILL ON MEDICATION. CALLER STATES IS RUNNING AN ADULT CARE FACILITY
Outstanding Inspections
Case Number: T06DV00590
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 15
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected | ||
| NPO - UNSECURED BUILD OR STRUC | None | Not Inspected | ||
| VIOL(BL) - DETACHED STRUCTURES | None | Not Inspected | ||
| VIOL(BL) - LIVING AREAS | None | Not Inspected | ||
| NPO(EL)-MAIN/PANEL/SUB/DISCONT | None | Not Inspected | ||
| VIOL(EL)-SUBPANELS/DISCONNECTS | None | Not Inspected | ||
| NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
| NPO(PL)-SEWAGE DISPOSAL (SYS) | None | Not Inspected | ||
| NPO(PL)-WATER HEATERS | None | Not Inspected | ||
| NPO(HC)-COOLING | None | Not Inspected | ||
| NPO(HC)-NO VENTILATION | None | Not Inspected | ||
| NPO(HC)-HEATING & VENTILATION | None | Not Inspected | ||
| VIOL(SA) - BATHS | None | Not Inspected | ||
| VIOL(SA) - KITCHEN | None | Not Inspected | ||
| NPO - SMOKE ALARMS | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T06DV00590
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2006 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Approved | VISITED SITE ON INITIAL INSP. MET WITH INSP. R. DIAZ, CHIEF CORDINATOR DEBBIE, AND IN HOSE MANAGER BRIAN. COMPLAINT STATED PROBLEMS WITH COOLING. WALKED INTERIOR AND EXTERIOR OF STRUCTURE TO CHECK FOR MIN- HOUSING VIOLATIONS AND ZONING VIOLATIONS - FINDINGS ARE AS FOLLOWS. FIRE SAFETY SMOKE DETECTORS WERE PRESENT AND FOUND TO BE WORKING, NO EGRESS ISSUE WERE PRESENT. ELECTRICAL ELECTRICAL SYSTEMS WERE CHECKED 1) COVER PLATE MISSING IN EASTSIDE MDDLE ROOM. TEST EQUIPTMENT WAS USED ON RECEPTACLES AND ALL TESTED OUT GOOD. GFCI WAS TESTED AND WORKING IN BATH ROOMS. 2) CHECKED SERVICE DISCONNECT FOUND 1-15 AMP CIRCUIT CONNECTION LOOSE AT BREAKER. 3) EXTERIOR LIGHT FIXTURE BY SLIDING GLASS DOOR WAS FOUND LOOSE. 4) AC WALL UNITS IN CONVERTED CARPORT AND 2ND STRUCTURE IN BACK ARE NOT ON REQUIRED SEPERATE CIRCUITS. EXISTING SERVICE IS 125 AND APPEARS TO BE MAXED OUT. 2ND STRUCTURE IS USED AS HABITABLE SPACE PLUMBING CHECK FOR PERMIT - NO PLUMBING ONLY ELECTRICAL. 1/2 PVC PIPING FROM ABANDONED WATER SOFTNER RUNS ALONG CONVERTED CARPORT WALL AND IS BROKEN AND NOT SECURED TO WALL. MECHNICAL EXHAUST MOTOR WAS CHECKED AND FOUND TO BE WORKING. HEATING AND COOLING 1) CHECKED FURNACE CLOSET, LARGE AMOUNTS OF DUST AND COMBUSTIBLE LINT PRESENT THROUGH OUT CLOSET. HOT WATER HEATER AND FURNACE 2) FURNACE WAS FOUND WITH ILLEGALLLY INSTALLED FLEX PIPING IN SIDE FURNACE CONNECTED TO GAS VALVE. INTERIOR FEATURES KITCHEN CABINETS DRAWERS AND DOORS HAVE NOT BEEN MAINTAINED, SEVERAL DOORS AND DRAWERS WERE FOUND MISSING DRAWER FACES AND LOOSE AT HINGES. WEATHER PROOFING CONVERTED CARPORT ENTRY DOOR LACKING WATHER STRIPPING ECIDENCED BY LARGE AMOUNTS OF LIGHT SHINNING THROUGH AT TOP AND BOTTOM W/O/P APPEARS CARPORT HAS BEEN CONVERTED TO LIVING SPACE DNR INSPECTOR HAD STAFF CHECK FOR PERMIT NO WERE FOUND. WILL CHECK RECORDS AT D.S.D. RECORDS SEC. ALSO PATIO/PORCH HAS BEEN ATTACHED TO MAIN STRUCTURE IN A HAZARDOUS MANNER. 2X6 BEAMS HAVE BEEN SPLCED TOGETHER AT NORTH SIDE OF MAIN STRUCTURE WITH OUT PROPER ATTACHING HARDWARE. PICTURES WERE TAKEN. COOLER MASTER COOL COOLER LACKS SERVICE, PADS WERE FOUND WITH LARGE ABOUTS OF SEDIMENT, TOP 4" OF PAD ARE NOT WET, INDICATING WATER DISTRABUTION PIPE IS CLOGED AND REQUIRES SERVICING. ALSO ELECTRICAL CORD SHEETING IS CRACKED AND EXPOSING ELECTRICAL CONDUCTOR. NOT FOR W/O/P : 2"X6" PORCH BEAMS ARE RESTING ON STRUCTURES ROOF. |
| 05/09/2007 | INSP - FOLLOW UP CODE ENFORCE | HLOPEZ | Approved | RECEIVED FAX FROM ARICO REGARDING CO TEST RESULTS FOR HEATING APPLIANCE. UNIT WAS DEEMED IN GOOD WORKING ORDER AND CO READING WAS AT 2 PARTS PER MILLION. CONTACTED SW GAS TECH SUPERVISOR, WENT OVER ALLOWABLE CO LIMITS AND READING OF 2 PARTS PER MILLION ARE ACCEPTABLE. PROPERTY OWNER HAS COMPLIED WITH NOV REQUEST. CASE WILL BE MARKED AS COMPLIANCE.PN |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T06DV00590
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 06/28/2006 | CONTACTED BY PHONE |
| 10/26/2006 | CONTACTED IN PERSON |
| 03/22/2007 | NOTICE OF VIOLATION ISSUED |
| 06/25/2007 | VIOLATION CLOSED |