Case: T06DV00185

Parcel: 12213090E


Addresses:

1275 N WALNUT BL

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
03/22/2006 INSP - INITIAL CODE ENFORCMENT Approved SITE INSPECTION WITH TENANT, WIFE AND CHILD (3 YEARS OLD) AND A BABY ON THE WAY.

INSPECTION FINDINGS:
-LIVING ROOM; FRONT DOOR LACKING PROPER WEATHER STRIPPING
-TENANT CONCERNED ABOUT CEILING (WOOD PANEL) NO VIOLATION
-TRANSITION STRIP LACKING BETWEEN CARPET AND TILE, LIVING ROOM TO HALLWAY.
-OPEN GROUND RECEPTICLE IN HALLWAY.
KITCHEN: NO GFI ABOVE COUNTER TOP.
-CABINETS PEELING ABOVE STOVE, WOOD PARTICLES FALLING IN FOOD BEING COOKED ON STOVE
-WATER AND HEATER CLOSET; FLOORING IS WOOD, SHOULD BE METAL OR FIRE RESISTANT
-HALLWAY: SMOKE DETECTOR HARDWIRED, WORKING
-EAST BEDROOM:WINDOW DOES NOT LOCK
-BATHROOM:VENT DOES NOT WORK
-MAIN BEDROOM: TENANT DID NOT WANT ME INSIDE

MAIN SERVICE PANEL: DUAL METER # AMR3-23358
50 AMP SERVICE, NO ISSUES
REAR YARD: ILLEGAL PORCH 4 2X4 USED AS HEADERS
NO HANGERS, 2X4 RAFTERS, POST LACKS PROPER HARDWARE.
BIRD BOARD: EVIDENCE OF WOOD PECKERS.

HALLWAY OUTLET/LIGHT SWITCH, MULTIPLE WIRES, GROUNDS TWISTED TOGETHER, NOT DONE CORRECTLY, OTHER OUTLETS SHOW SAME.

OWNER TO INSURE PROPER WIRING/ SUPERVISOR SAYS NO.