Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

VOID

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

03/06/2006

Applicant:

TARAZON EMMA & CRUZ MARTHA & ANDRADE CENIA &

Description:

FUSES IN PANEL BOX WERE MELTED, SWITCHES HAVE BEEN REPLACED. CUPBOARDS DO NOT FUNCTION PROPERLY DUE TO WATER DAMAGE. UNDER THE SINK THE BOTTOM PLANK IS SOFT AND BOWING INWARD.

Outstanding Inspections

Case Number: T06DV00185
Case Status: VOID
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: VOID
Case Number: T06DV00185
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
03/22/2006 INSP - INITIAL CODE ENFORCMENT MROMERO Approved SITE INSPECTION WITH TENANT, WIFE AND CHILD (3 YEARS OLD) AND A BABY ON THE WAY. INSPECTION FINDINGS: -LIVING ROOM; FRONT DOOR LACKING PROPER WEATHER STRIPPING -TENANT CONCERNED ABOUT CEILING (WOOD PANEL) NO VIOLATION -TRANSITION STRIP LACKING BETWEEN CARPET AND TILE, LIVING ROOM TO HALLWAY. -OPEN GROUND RECEPTICLE IN HALLWAY. KITCHEN: NO GFI ABOVE COUNTER TOP. -CABINETS PEELING ABOVE STOVE, WOOD PARTICLES FALLING IN FOOD BEING COOKED ON STOVE -WATER AND HEATER CLOSET; FLOORING IS WOOD, SHOULD BE METAL OR FIRE RESISTANT -HALLWAY: SMOKE DETECTOR HARDWIRED, WORKING -EAST BEDROOM:WINDOW DOES NOT LOCK -BATHROOM:VENT DOES NOT WORK -MAIN BEDROOM: TENANT DID NOT WANT ME INSIDE MAIN SERVICE PANEL: DUAL METER # AMR3-23358 50 AMP SERVICE, NO ISSUES REAR YARD: ILLEGAL PORCH 4 2X4 USED AS HEADERS NO HANGERS, 2X4 RAFTERS, POST LACKS PROPER HARDWARE. BIRD BOARD: EVIDENCE OF WOOD PECKERS. HALLWAY OUTLET/LIGHT SWITCH, MULTIPLE WIRES, GROUNDS TWISTED TOGETHER, NOT DONE CORRECTLY, OTHER OUTLETS SHOW SAME. OWNER TO INSURE PROPER WIRING/ SUPERVISOR SAYS NO.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T06DV00185
Case Status: VOID
Total Completed Case Activity Conditions: 1
Date Name
01/16/2007 VIOLATION CLOSED

Documents

File Name Document Type  
NOTES 03-17-06.PDF DOCUMENTS VIEW
NOTES 12-21-06.PDF DOCUMENTS VIEW