Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* CLOSET FLANGES COMPLETE |
|
| 10/10/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES ALL EXCEPT 1163, 1151 |
|
| 10/09/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) CLOSET FLANGES SEE D 1ST LEVEL SOUTH CORRIDOR OK 2) REQUESTED PLAN REVISIONS RECEIVED 3) PLANS REVISION OK 4) NEED TO CHECK GAS REGULATOR VENTS |
|
| 10/07/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 3" FITTINGS GLUED INSIDE 4" PIPE NOT ACCEPTABLE ALSO, SECURE FLANGES KEEP ALL OPEN PIPES CAPPED UNTIL FIXTURES ARE SET |
|
| 09/29/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 09/22/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SEC. D 2ND LEVEL CLOSET FLANGES AND HAMMER ARRESTORS OK |
|
| 09/17/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES A BUILDING 2ND LEVEL OK RECEIVED PLAN REVS FOR ACCESSIBLE SHOWERS AND WATER PIPING. RWL REVISIONS ARE NOT ACCURATE. |
|
| 09/12/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* C-SECTION CLOSET FLANGES OK HAMMER ARRESTORS OK A SECTION 3" OFFSET FLANGES GLUED INSIDE 4" PIPE; PROVIDE FLANGE LISTING AND INSTALLATION INSTRUCTIONS. |
|
| 09/03/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - LAUNDRY WATER PIPING OK TO COVER - 2215 & 2213 PIPING OK TO COVER - REDLINE DELETED DRAIN AND REMOVE PIPING TO RE-VENT ON 3RD FLOOR - PROVIDE PLAN REVISIONS PREVIOUSLY REQUESTED |
|
| 09/02/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELED |
|
| 08/29/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/28/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* BAR AREA OK EMPLOYEE TR PIPE INSULATION OK TO COVER |
|
| 08/26/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* EMPLOYEE RM. 108 DWV TEST OK INSULATE WATER TUBING FOR REINSPECTION BAR AREA: SEPARATE, INSULATE SECURE TUBING IN LAUNDRY PROVIDE APPROVED CPVC TRANSITION FITTINGS FOR CONCEALED LOCATIONS |
|
| 08/25/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/19/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CW EXP LOOPS AT RMS. 1308 AND 1301 PER PSK19 DATED 7/28/08 |
|
| 08/08/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 2' LOOP ON CW, SEC D RM 1254 |
|
| 08/04/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SEC. C 2ND LEVEL 2' OFFSET ON CW AT RM. 1233 OK SEC. B 1ST LEVEL CLOSET FLANGES OK SEC. B 2ND LEVEL HAMMER ARRESTORS OK |
|
| 07/23/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 2ND LEVEL SEC. C CLOSET FLANGES OK TEMP CAPS SHOULD BE INSTALLED UNTIL CLOSET IS SET TO PREVENT THE ESCAPE OF SEWER GASES INTO THE BUILDING |
|
| 07/17/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. THE PLAN REVISION REQUIRED AND REQUESTED ON FEB 20TH, MARCH 19TH, APRIL 17TH, MAY 15 AND 29TH WHICH WAS PROVIDED ON JULY 16TH FOR THE CHANGE OF MATERIAL TYPE ON THE MAIN DOMESTIC WATER DISTRIBUTION SYSTEM DOES NOT APPEAR TO SATISFY THE REQUIREMENTS OF THE 2003 UPC IS #20 SEC. 313.7; THERMAL EXPANSION CPVC PIPING INSTALLED IN UNCONDITIONED ATTIC SPACE BASED ON MY CONVERSATIONS WITH THE CITIES MECHANICAL ENGINEER AND DEPUTY DIRECTOR YOU ARE REQUESTED TO HAVE YOUR ENGINEER CONTACT ROBERT SHERRY @ 837-4914 TO RESOLVE THIS CONCERN OR NO APPROVALS WILL BE ISSUED. |
|
| 07/11/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SEC B LEVEL 3 CLOSET FLANGES OK |
|
| 07/08/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* FLOOR DRAINS FOR RMS 2213, 2215, 2313, 2315 AND 2316 OK FS PIPING FOR SOFTENER DRAIN RM 2315 OK PROVIDE PLAN REV. FOR ADDITIONAL DRAINAGE INSTALL TRAP PRIMER WATER PIPING OK TO INSULATE |
|
| 07/07/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* NOT READY PER JAMES SUPER NOT IN OFFICE NOTE: DO NOT COVER GAS AND RWLS SEC. A UNTIL REDLINES HAVE BEEN PROVIDED AND COMPARED TO INSTALLATION. |
|
| 07/02/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES 3RD LEVEL B BLD FROM SOUTH TO NORTH TO UNIT #1319 GOING WEST |
|
| 06/27/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES 2ND LEVEL B OK |
|
| 06/26/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES 2ND LEVEL B OK WATER TEST TOILETS PRIOR TO CAULKING CONN TO FLOOR |
|
| 06/24/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 4" FD PIPING FROM BOILER 1 ON ROOF. TEST OK. RED LINE LOCATION OF DRAIN AND PIPING ON APPROVED PLANS |
|
| 06/23/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SEC. D PIPE INSULATION OK. TEST ON TUBS & SHWRS OK SEC. A PIPE INSULATION OK. TEST ON TUBS & SHWRS OK |
|
| 06/19/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SEC D - SOUTH & WEST SIDE PIPE INSULATION OK SEC B - WEST END 2ND LEVEL, CLOSET FLANGES OK |
|
| 06/18/2008 | PLUMBING - INTERMEDIATE | Partial Approval | SEC D DWV TESTING OK NEED TO SEE TEST OF TUBS & SHWRS SEC A WATER MAINS OK TO INSULATE |
|
| 06/16/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SEC. A DWV W/TEST THRU ROOF OK 1ST LEVEL ABV CEILING OK PROVIDE REDLINES AND REVISIONS FOR CHANGES TO RWLS INCLUDE 270 DEG. CHANGES OF DIRECTION CLOSET BOOTS SHALL BE BRASS OR EQUALLY CORROSION RESISTANT (STAINLESS) |
|
| 06/13/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SEC D 2ND LEVEL PIPE INSULATION AND STRAPPING OK |
|
| 06/11/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SEC D SOUTH OF 1154 INSULATION AND STRAPPING OK TO COVER RWL's RM. 1246 W/TEST OK |
|
| 06/10/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* ISOLATE PEX FROM METAL AND SECURE W/PIPE CLAMPS SEAL JOINTS IN PIPE INSULATION W/ARMAFLEX 520 ADHESIVE PROVIDE TEST OK RWL's AND SECURE VERTICAL DROPS |
|
| 06/04/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PIPE INSULATION IN CORRIDORS 227 AND 228 AND RMS ON BOTH SIDES OF CORRIDORS OK |
|
| 06/03/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* COMPLETE INSULATION STRAP/SECURE TUBING PAY ATTENTION TO LAUNDRY AND VENT SOVS SECURE CPVC W/PROPER ALIGNMENT USE CONTACT CEMENT TO SEAL JOINTS IN ARMORFLEX |
|
| 05/30/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. KIT. RM 147 OK TO COVER WALLS 2. ABOVE CEILING GAS PIPING IS NOT RATED PER PLAN 3. PRESSURE REGULATOR IS NOT LOCATED PER PLAN 4. REDLINE ROUTING CHANGE ON APPROVED PLAN AND PROVIDE ENGINEER APPROVAL FOR CHANGE 5. ALSO, NEED TO INSPECT ABOVE CEILING PIPING SUPPORTS ON WATER, GAS AND DWV 6. FD AND PIPING IN CEILING ABV RM 1130 IS OK 7. PROVIDE 24" AP 8. BUILDING D EAST OF CONSTRUCTION CORRIDOR -- OK TO COVER 9. DO NOT COVER ANY PIPING WEST OF CORRIDOR |
|
| 05/29/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SEC. D WATER PIPING UNDER TEST. PROVIDE APPROVED PLANS, REDLINE LOOP OFFSET LOCATIONS, INSULATE, STRAP AND SECURE ALL TUBING. DWV CORRECTIONS OK. SECURE PIPING. RECALL FOR INSP. SEC. A RMS. 168, 268 DWV TEST THRU ROOF OK RMS 168, 162-163 OK TO COVER RMS 155-160 OK TO COVER KITCHEN AREA CORRECT CW SIZING AT DISP. INSTALL TRAP PRIMER DIST. OR SEPARATE TPS AND UNIONS. PROVIDE ACCESS. INSTALL GAS PIPING PER YOUR PIPING SCHEMATIC DRAWING INSTALL MISSING PIPE SUPPORTS ON GAS, VENT AND WATER |
|
| 05/28/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SEC. A CORRECT WATER PIPE SIZING AND SUPPORTS 2. OK TO INSULATE 3. SUPPORT & SECURE PEX W/APPROVED PEX SUPPORTS 4. NO ADHESIVE TAPE 5. CO REQUIRED FOR MS 6. WYE PATTERN FITTINGS REQUIRED FOR FOOT VENTS ON ISLAND LOOPS 7. ABV CEILING AT BOILER LOCATION NEED AN ACCESS PANEL FOR CPVC THREADED CONNECTIONS; INSULATION AND SUPPORT 8. 4" FD IS NOT PROPERLY VENTED |
|
| 05/27/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV W/TEST ON SEC. D SOUTH OF 1154 OK EXCEPT FOR SLOPE IN RM 1150 AND SOME PIPE SUPPORTS NEEDED. STILL NEED WATER TEST ON SHOWERS AND TUBS. |
|
| 05/23/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 05/15/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - CORRECTIONS IN SEC. C OK - SOME HANGERS INSTALLED ABV CEILING - HAVE BEEN REMOVED FOR SHEETROCK - RECALL FOR INSP. AFTER REINSTALLING HANGERS ON TRAP ARMS - PLEASE PROVIDE PLAN REVISIONS REQUESTED ON 3/19/08 FOR WATER DISTRIBUTION SYSTEM |
|
| 05/08/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEC. A NOT UNDER TEST. MISSING FHA STRAPS AND SUPPORTS |
|
| 04/24/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV SEC C NORTH EXCEPT UNIT 1125 LEAK AT FLOOR OF LAUNDRY AND UNIT 1290 VENT BEHIND SHOWER (1ST & 2ND LEVEL) WATER DISTRIBUTION & INSULATION OK |
|
| 04/22/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELED |
|
| 04/21/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* PM INSP REQUESTED 2PM CONTRACTOR NOT READY |
|
| 04/18/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV SEC C SOUTH OF UNIT 1186 BOTH FLOORS TEST OK INSULATE & SECURE HW PIPING SUPPORT PIPING AS NEEDED |
|
| 04/17/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* NOTE: ANY CHANGES MADE IN A SECTION SHALL BE INSPECTED. CPVC MAIN WATER DISTRIBUTION SEC. C INSTALLED PER ENGINEERS DIRECTIVE W/2' LOOP INSTALLED AT 100' ON HW ONLY NEED PLAN REV. FOR FINAL APPROVAL OK TO INSULATE ALL HW PIPING, STILL NEED TO SEE PIPING STRAPS. DWV TEST ON SOUTH HALF OF SEC. C 2ND LEVEL ONLY OK 1ST LEVEL REQUIRES CORRECTIONS & RETEST SUPPORT PIPING PLUMB. CLOSET RISERS TEST TO SHOWER HEADS FOAM WRAP AT SLAB |
|
| 04/16/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 04/11/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* - BUILDING C PIPING W/TEST - PROVIDE LETTER FOR CHANGE FROM WELDED TO THREADED FITTINGS ON 2" BLK PIPING |
|
| 03/27/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* STILL NEED TO SEE HW MAIN PIPING INSULATION SEAL JOINTS W/ADHESIVE |
|
| 03/26/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - 2ND & 3RD LEVEL PIPE INSULATIONS OK - TUB & SHWRS OK - RD'S TEST OK - PIPING INSTALLED PER P.3.1.2 - RECALL FOR CORRECTION IN RM 1301 AND FOR PIPE SUPPORTS |
|
| 03/24/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1ST LEVEL B SEC PIPE INSULATION OK 2ND LEVEL TEST ON TUBS & SHWRS OK PROVIDE ACCESS AT CIRC. SETTERS DO NOT STAPLE INSULATION TO DRAIN PIPING |
|
| 03/19/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CPVC WATER MAINS BUILDING B INSTALLED PER UNAPPROVED PSK-1B REV. PROVIDE CITY APPROVED PLAN REVISIONS WHICH INCLUDE MATERIAL TYPE AND METHODS USED TO CONTROL EXPANSION AND CONTRACTION OF CPVC. PEX INSTALLED PER DRAWING SUPPLIED BY TONY. ATTACH TO APPROVED SET AND PROVIDE PLAN REVISIONS FOR FINAL APPROVAL |
|
| 03/18/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 03/17/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* BUILDING B DWV W/TEST THRU ROOF OK EXCEPT FOR UNIT 1113 |
|
| 03/14/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 03/13/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV TEST TO LEVEL 3 GAS NOT PER PLAN NOTE: ALL CHANGES FROM PLAN REQUIRE CITY APPROVED REVISIONS, REDLINES SHALL BE ON SITE FOR INSPECTIONS. |
|
| 03/03/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV WATER TEST BUILD B ALL EXCEPT UNIT #1113 1ST LEVEL ONLY |
|
| 02/28/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* SOIL PIPING - TEST DOWN WATER NOT PER PLAN I NEED AT LEAST REDLINES TO INSPECT FROM SEAL PIPE INSULATION |
|
| 02/26/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* DWV PIPING SHALL BE TESTED TO 10' ABOVE FITTINGS AIR TEST ON PEX RMS 1116-1121 PEX WATER PIPING IS NOT INSTALLED PER P6.1 PROVIDE APPROVED PLAN REVISIONS |
|
| 02/20/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO USE CPVC WATER PIPING AS NOTED BY L.PANOPIO PROVIDE A DETAIL TO CONTROL EXPANSION AND CONTRACTION OF PLASTIC PIPING. REFERENCE UPC IS #20 SECTION 2.4 |
|
| 02/19/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* RECEIVED PLUMBING DIAGRAM W/NOTE ALLOWING CPVC WATER PIPING. DO NOT COVER FITTINGS PRIOR TO TEST WILL ALLOW AIR TEST ON PEX TUBING ONLY |