Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/20/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 10/01/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK 2ND FLOOR "D" HALL OK LIGHTS AT SOUTH CANOPY OK BONDING FOR BOLLARD - 680.26 |
|
| 09/20/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 09/19/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 09/10/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK POLE BASES @ CIRCLE DRIVEWAY 2. OK CEILING CORRIDOR BLDG. C - 2ND FLOOR 3. OK WALLS & CEILINGS STAIRCASE #7 |
|
| 09/08/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK U.G FOR SPOT LIGHT NORTH SIDE OF BUILDING (6) TOTAL 2. OK CEILING KITCHEN EXCEPT AREA BY DINING ROOM 3. OK WALLS & CEILINGS AT 3RD FLOOR ELEVATOR LOBBY AND WATER SOFTENER RM |
|
| 08/29/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/28/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 08/25/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio PLEASE PAY REINSPECTION FEE BEFORE NEXT INSPECTION 1. FINISH VDV 2. FINISH ABOVE CEILING AS LAST INSPECTION |
|
| 08/22/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS & LID SES "D" |
|
| 08/21/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 08/20/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* KITCHEN 1. FINISH M/C CABLES 2. SUPPORT M/C AS PER 300.11 3. SUPPORT M/C TO OUTLET BOX 12" 4. FINISH SUPPORTING FIRE ALARM CABLE 5. A/C DISCONNECT TO BE ACCESSIBLE AND LABELED 1C/1D: OK DROPS HARD LIDS LEAVE ACCESS TO CHECK BOND LUG TO FIRE PIPE |
|
| 08/19/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/18/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/16/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) FINISH STAIR #2 PER INSPECTION ON 8/14/08 2) CLEAN EXCESS DIRT AND FOREIGN MATERIAL FROM PANELS 3) TIGHTEN MAIN LUG TERMINATIONS AND ALL ALUMINUM 4) FILL UNUSED OPENINGS IN PANELS 5) RECEIVED CHECKS #108626 FOR $150 & CHECK #108627 FOR $75 6) 314.20 ON LIGHT BOXES IN CEILING 7) OK STAIRWELL #1 8) OK PVC UNDER POOL ROOM 9) OK PVC EAST OF PALM TREES SOUTH COURTYARD 10) OK TMPP 1125-1141, 1180-1190, 1226-1244 AND 1277-1290 EXCEPT 1133-1183 |
|
| 08/15/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
|
| 08/14/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* STAIR #2: SUPPORT FIRE ALARM CABLE 760.24 #1C: 1. SUPPORT VDV CABLING 725.24 2. REMOVE TEMP LIGHT 3. USE APPROVED LISTED ADAPTOR FOR BOND CLAMP #1A 1. SUPPORT FIXTURE WHIP OFF OF GRID 2. ATTACH FIXTURE 410.16 |
|
| 08/13/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK PVC AT PALM TREES SOUTH COURTYARD 1. NEED LISTING OF TORQUE SES "C" |
|
| 08/11/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* UNDERGROUND COVERED IN COURTYARD WITHOUT INSPECTIONS - PUT HOLE AS DISCUSSED |
|
| 08/08/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 08/07/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK 137 & 134 ROUGH 2) OK 2C HARD LIDS |
|
| 08/05/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 08/04/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK UNITS 1160-1166 |
|
| 08/01/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. MAINTAIN FIRE WALL SEPARATION 2. SUPPORT NM CABLES ABOVE PANEL |
|
| 07/31/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* A REFEE WILL BE ASSESSED FOR UNNECESSARY INSPECTIONS PER ADMIN. CODES |
|
| 07/30/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* NO WORK PROGRESS |
|
| 07/29/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK UNITS 1157-1159 & 1167 |
|
| 07/28/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. MAINTAIN FIRE WALL SEPARATIONS AT BATH LIGHTS OK UNITS 1151-1156; 1168-1171 --- AFTER CORRECTIONS |
|
| 07/25/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CANCELED |
|
| 07/24/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1145-1150 1176-1172 OK ROUGH UNITS 1145-1150/1172-1176 RECEIVED CHECK #0606743797 - $1,500.00 |
|
| 07/18/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 07/17/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* OK TEMP POWER 1108-1110, 1117-1119, 1208-1210, 1217-1219 1308-1310, 1317-1319 1. CLEAN EXCESS DIRT FROM PANELS |
|
| 07/15/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK 2-A HARD LID |
|
| 07/08/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 07/07/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS 2A COMMON AREA |
|
| 07/03/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* DENIED 2A PARTIAL 2D OK 1210-1266 |
|
| 07/02/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
|
| 07/01/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK 1259 & 1267 |
|
| 06/30/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CANCELED |
|
| 06/27/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. SUPPORT VDV ABOVE CEILING 2D ELECTRIC ROOM OK 2D CORRIDOR LID ONLY |
|
| 06/26/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK "D" CORRIDOR CENTER TO AROUND AND END 1257 |
|
| 06/24/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK DINING ROOM WALLS ONLY 1250-1255 OK ROUGH 1269-1271 OK ROUGH |
|
| 06/23/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 06/19/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK 2C SOUTHEAST STAIRWELL & ELECTRIC ROOM OK ENTRY ARCH RESTAURANT |
|
| 06/18/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK 1245-1249 1272-1276 |
|
| 06/16/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK ENTRY PORTE CACHE 1. POTHOLE UNDERGROUND CONDUITS FOR INSPECTION |
|
| 06/11/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. FINISH BISTRO ENTRANCE OK 1A HARD LID EXCEPT AS NOTED |
|
| 06/05/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK 3B SOFFITS 1. BRING FIRE ALARM INTO BOX |
|
| 06/03/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* FINISH ELECTRIC AND VDV CABLING 3B |
|
| 06/02/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK ROUGH 1139-1141, 1180-1182 |
|
| 05/30/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1132-1138 1183-1187 OK UNITS 1132-1138/1183-1187 ROUGH 1. GROUND JUNCTION BOXES FOR LIGHTS |
|
| 05/29/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. FURR OUT 1191 OK 1125-1131 1188-1191 ROUGH EXCEPT 1191 PANEL |
|
| 05/28/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK #2 CORRIDOR B-C OK #1 CORRIDOR A,B,C 1. FINISH UNITS |
|
| 05/27/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK NORTH EXTERIOR 1160-1163 AND 1260-1263 ONLY NO MORE PARTIAL ROOMS FINISH UNITS TO INSPECT |
|
| 05/23/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS 1A OK CORRIDOR 2C |
|
| 05/22/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK 2-1 1/2" GATE ACCESS RACEWAYS 2) DO NOT ROCK 3) VDV CABELING TO BE SUPPORTED TO STRUCTURE NOT OFF OF OTHER WIRING METHODS 4) FINISH ALL WIRING TO ROOMS (VDV) |
|
| 05/21/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* VERIFY COAX CABLE HARD LINE FOR LISTING |
|
| 05/20/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* EXTERIOR WALLS TO COURTYARD ONLY #1125-1129 |
|
| 05/19/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. PROTECT VDV CABLING FROM SHARP METAL EDGES 2. SUPPORT VDV CABLING OK WALLS ONLY CORRIDOR 2C |
|
| 05/15/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. PROPERLY SUPPORT CONDUITS 2. TIGHTEN LOOSE FITTINGS |
|
| 05/14/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK UNITS 1238-1244 1277-1282 |
|
| 05/13/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK 1207, 1230-1237, 1283-1286 |
|
| 05/12/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CANCELED |
|
| 05/09/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK ROUGH 1225-1229 1288-1291 |
|
| 05/08/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. SUPPORT FIRE ALARM CABLES WITHIN 8" OF BOXES 2. SUPPORT NM CABLE 12" PANEL AND ENTRY TO FLEX 3. FIRE WALL SEPARATIONS 4. BACK BRACES FOR 4-GANG BOXES 5. MISSING EXHAUST FANS |
|
| 05/06/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. INSTALL FITTING INTO BOX 2. BOXES OVERFILLED AT CANS OK 1ST FLOOR CORRIDOR "B" AFTER CORRECTIONS |
|
| 05/02/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 602-725-0607 OK 2ND FLOOR OFFICES & HALL HARD LIDS OK 3RD FLOOR PRE-ROCK HALL LID |
|
| 05/01/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio 3RD FLOOR 1. MAINTAIN FIREWALL SEPARATION 2. SUPPORT FIRE ALARM CABLE AT BOXES 2ND FLOOR 1. DRYWALL NOT ALL REMOVED PLEASE PAY REFEE AS DISCUSSED |
|
| 04/30/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. SUPPORT VDV CABLING 2. REMOVE OFFICE CEILINGS TO INSPECT 2ND FLOOR 3. FINISH HALL 2ND FLOOR 4. VERIFY FIRESTOPPING INSPECTION *314.20 WILL APPLY |
|
| 04/29/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK UNITS 1109-1117 |
|
| 04/28/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1106-1109 1117-1121 |
|
| 04/25/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 04/24/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK UNITS 1124, 1123, 1102, 1122, 1104, 1105 "B" FIRST FLOOR |
|
| 04/23/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK 3RD FLOOR INTERIOR BUILDING B |
|
| 04/22/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS & HARD CEILINGS 1301-1307/1320-1324 |
|
| 04/21/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* MAINTAIN FIRE SEPARATION OK 2ND FLOOR CORRIDOR BUILDING "B" |
|
| 04/18/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* MAINTAIN FIRE WALL SEPARATION - 300.21 |
|
| 04/15/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK 1101 & 1103 MODELS |
|
| 04/14/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* MAINTAIN FIREWALL SEPARATION OF BOXES OK 2ND FLOOR 1201-1206, 1220-1224 (11 UNITS) |
|
| 04/11/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK FLEX & CONDUIT LIVING BUILDINGS |
|
| 04/10/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK VDV CABLING EAST 1/2 2ND FLOOR ROOMS |
|
| 04/09/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. SUPPORT VDV CABLING AS PER 725.6, 800.6, 760.6 2. PROTECT VDV CABLING AT MEDIA CENTERS |
|
| 04/07/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK ELEVATOR #3 WALLS & HARD CEILING |
|
| 04/04/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS ELEVATOR ROOM OK 2 GROUND RODS & #4 SDBC |
|
| 04/03/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DO NOT DRY WALL 1. ELEVATOR ROOM - FINISH FLEX CONDUIT THROUGH STUDS 2. SUPPORT T-STAT WIRES IN WALL AND ABOVE CEILING 725.6 OK 120V M/C CABLE & BOXES |
|
| 03/24/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CANCELED |
|
| 03/21/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. FINISH HALLWAY WIRING 2. SECURE CABLE TO METAL BOXES - TIGHTEN CLAMPS 3. VERIFY USAGE OF EMT THROUGH FIRE WALLS AND LISTING FOR FITTINGS 4. FINISH WIRING CLOSET LIGHT #1111 5. CLOSET LIGHT S/L DAMAGED #1108 6. SECURE CABLE TO BOXES - MULTIGANG 7. WIRING DAMAGED #1107, 1106 8. WIRE SHEATHING TO EXTEND 1/4" INTO BOXES #1106 |
|
| 03/20/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 03/17/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK EXTERIOR WALLS 1301-1324 ONLY |
|
| 03/14/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK EXTERIOR WALLS 2ND FLOOR |
|
| 03/13/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. HAVE BUILDING INSPECTOR VERIFY FIRESTOPPING TOP PLATES & WALLS 2. PROTECT NM CABLE AT STUDS OK 1101-1124 AFTER CORRECTIONS EXTERIOR WALLS ONLY |
|
| 12/06/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK 7 - 4" CONTINUATION TO BUILDING "A" 1. STRAP NM CABLES ABOVE PANEL 12" *NEED TO SEE ELECTRICAL WIRING BEFORE 1ST LID (PRE-ROCK) |