Permit: T06CM06423

Parcel: 13320129C


Addresses:

6300 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
10/17/2008 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
09/11/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
09/04/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SCREEN WALL @ NW CORNER - WILMOT @ 4' - ABOVE SITE ELEVATION
08/27/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MONUMENT COMPLETE @ 8' ABOVE SITE ELEVATION
OK TO GROUT
08/21/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MONUMENT WALL @ 4'
ABOVE SITE LEVEL OK TO GROUT
08/14/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NW SCREEN WALL AND ENTRY MONUMENT BASE @ 52"-60" (24" ABOVE GRADE) POURED
08/11/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS @ SWIMMING POOL EQUIPMENT AREA @ 5'
OK TO GROUT
07/30/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BBQ AREA WALLS - GROUTED
07/22/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SCREEN WALL SE & EAST - TOPPED OUT @ 6'8" - OK TO GROUT
07/16/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST & SE PORTION OF SCREEN WALL @ 4' -- OK TO GROUT
07/15/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CMU SCREEN WALL NEEDS REBAR
07/02/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10 @ PIERS FOR TRELLISES IN N&S COURTYARDS @ 7'6"
OK TO GROUT
06/30/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
COLUMNS FOR COURTYARD PATIOS - 10 @ 4' -- GROUTED
06/27/2008 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
The inspector was unable to locate the job.| 945*
COULD NOT LOCATE SUPERINTENDENT AT AREA OF WORK

IT WOULD BE A GOOD IDEA TO LEAVE A PHONE # OR PUT UP SIGNS INDICATING WHERE SUPER'S OFFICE IS OR EVEN TELL ONE OF THE 15 GUYS I ASKED.
04/28/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TRASH ENCLOSURE @ 6'
OK TO GROUT
04/17/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TRASH ENCLOSURE & WASH OUT ROOM @ 4' -- GROUTED
03/14/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
STAIRWELL #8 @ 4' TO 8' -- OK TO GROUT
02/28/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
STAIRWELL #8, DOWELS IN PLACE WALL @ 48";
ROOM #367A WEST WALL @ 8'8"; WILMOT AREA SCREEN WALL
32' TO MAIN ENTRY AREA - OK TO GROUT PROGRESS AREAS
02/27/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
RETAINING WALL @ WILMOT - APPROX. 50' @ 40' ABOVE GRADE; STAIRWELL #8 WALL @ LINE L.5/17 @ 4' -- OK TO GROUT
02/14/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST SCREEN/RETAINING WALL @ WILMOT ROAD
APPROX. 225' @ 7'; 25' @ 4' - OK TO GROUT PROGRESS AREAS
01/24/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST RETAINING WALL @ 4'
APPROX. 150' @ WILMOT SIDE
01/17/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SCREEN WALL @ SW CORNER (WILMOT) @ 4' --
OK TO GROUT STAIRWELL #6 @ 4'
01/14/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BEAM CROSSOVER @ G.9/14.4 - TOPPED OUT
01/11/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CROSS BEAM CMU WALLS
#261 EXERCISE ROOM EAST WALL;
BALCONY/ROOM #260 @ 4' OK TO GROUT
01/04/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
REPAIR TO CMU WALL @ L.1/15-17 @ 8';
LINE L/16-M/16 @ 20'-24' - OK TO GROUT
01/03/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH FIRE WALL @ 24'-28' @ NE CORNER - OK TO GROUT
01/02/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES G.9/14.5-17; K/14.4-16; L/14.4-16
M/14.4-16, TOPPED OUT @ 20'-24' -- OK TO GROUT
12/28/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH FIREWALL @ F.5/11 TO F.5/12.6; F.5/12.6 TO G.5/12.6 ALL @ 24' TO 28' -- OK TO GROUT
12/26/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) NORTH FIRE WALL AT LINES F.5/12.6 TO G/12.6, G/12.6 TO G/14.4-OK TO GROUT
12/21/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) COMMON WALL AND LINE G/14.4 AT 12'-16'; FIREWALL AT LINE F.5/10-12.6 AT 16'-24'; F.5/10-13 AT 20'-28' OK TO GROUT PROGRESS AREAS
12/20/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
FIREWALL @ F.5/12.6 TO G/12.6; G/12.6 TO G/14.4 @ 8' TO 12' OK TO GROUT
12/19/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
THEATRE WALLS N&S @ 20' TO 24'
FIREWALL F.5/11-12 @ 8'-12' - OK TO GROUT PROGRESS AREAS
12/18/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
THEATRE #2159 NORTH & SOUTH WALLS @ 20'-24'
OK TO GROUT
12/17/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
N&S THEATER WALLS @ 16' - 20'; FIREWALL @ F/11 TO G/14.4 @ 8'-12'; TYPICAL WALL G/14.4 OK TO GROUT
12/14/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
12/13/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CORRIDOR SOUTH WALL: LINE L/13 TO L/16 @ 28' TO 31'
EAST WALL H/16 TO L-8/16 @ 24' TO 28'
TYPICAL WALL @ 16' TO 20' OK TO GROUT
12/12/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST FIREWALL H/17 TO L.5/17 @ 20'-24';
TYPICAL WALL CORRIDOR #2154 @ 16'-20'
SOUTH TYPICAL WALL LINE M/14 TO M/15 @ 24' TO 28'

OK TO GROUT PROGRESS AREAS
12/10/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
WILL RECALL FOR 12/12
12/06/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH FIRE WALL - 24'-28'; WEST TYPICAL WALL TOPPED OUT 10'4" -- OK TO GROUT
12/04/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TYPICAL WALL WEST @ 24' TO 28'
SOUTH WALL @ 16'
EAST WALL @ 8'-12'
EAST FIRE WALL @ 12'-16'
OK TO GROUT PROGRESS AREAS
11/30/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ BUILDING "A" WEST WALL TO 28 FOOT SOUTH WALL TO 16 FOOT AND SOUTH EAST HALF OF FIREWALL TO 12 FOOT -- OK TO GROUT
11/28/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
FIRE WALL (WEST) EAST WALL @ 28' TO 31'
#2146 SOUTH WALL @ 16'-20'; 8'-12'
#2148 N & E WALLS @ 4-8'
11/26/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST FIRE WALL @ 28' TO 31' - OK TO GROUT
11/16/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST FIRE WALL @ 24' TO 28'; TYPICAL WALL @ 16'-20'
LINE G.9/14.5 TO G.9/I -- OK TO GROUT
11/15/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST FIRE WALL @ 24' - GROUTED - SPECIAL INSPECTED
11/13/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) PARTIAL WEST FIRE WALL AT 12'-16'; TYPICAL WALL G/12.6 TO G-7/12-6 AT 10'-4"-SOUTH SCREEN WALL MID TO WEST (WILMOT) APPROX 75' AT 4'-GROUTED
11/07/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH SCREEN WALL MID TO MID-WEST @ 4'
OK TO GROUT
11/06/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST FIRE WALL: LINE G.8/8 TO J/9 @ 16'
NORTH FIRE WALL, LINE F.5/12.6 TO G/14.4
TYPICAL WALL G/12.6 TO G.2/14.6 @ 4' --
OK TO GROUT PROGRESS AREAS
11/05/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
WILL RECALL
10/31/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST FIRE WALL @ 12' OK TO GROUT
10/25/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH ELEVATOR # 34' -- OK TO GROUT
10/24/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
10/23/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH SCREEN WALL
EAST PORTION APPROX. 100' @ 5'4" OK TO GROUT
10/22/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH SCREEN WALLS APPROX. 20' @ 4'
NORTH ELEVATOR @ 31'
FIREWALLS (7.9/8 TO I/10; CORRIDOR #2154 @ 8' OK TO GROUT)
10/19/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH SCREEN WALL (SE PORTION) APPROX. 50' @ 4' - OK TO GROUT
10/17/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH ELEVATOR @ 26' -- OK TO GROUT
10/15/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST ELEVATOR TOPPED OUT @ 38' -- OK TO GROUT
10/12/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :
EAST ELEVATOR BLDG B @ 34' -- OK TO GROUT
10/10/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
10/08/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS @ 32" - G.9/15-16, G.9/15 TO J/15; J/15 TO J/16
G/12.6 TO G/14.4; OK TO GROUT @ 32"
10/04/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH ELEVATOR AT 28'-8" OK TO GROUT
10/03/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH ELEVATOR @ 26'; NORTH ELEVATOR @ 16'
WEST FIRE WALL @ BLDG A, LINE G.8/8 TO L.5/9 -
OK TO GROUT
10/02/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ELEVATOR SHAFTS
10/01/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
NOT READY WILL RECALL FOR 2 OCT
09/28/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH, SOUTH, EAST ELEVATORS @ 18' -- OK TO GROUT
09/27/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
WILL RECALL
09/26/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BLDG A ELEV @ 14'; BLDG B ELEV @ 10'; BLDG C ELEV @ 10'
OK TO GROUT
09/24/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BLDG B ELEVATOR @ 4' TO 8'
BLDG D ELEVATOR @ 4' TO 8'
WALL L.1/11 TO L.1/14 TO L.1/14.4 TO M/14.4 -- OK TO GROUT
09/21/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
09/19/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALLS AT 4' LINES L.8/9 TO L.8/15 OK TO GOUT
2) F3 FOOTINGS LINE FF/30 TO DD/30
3) F-7-F8 FOOTINGS LINE AA/28 TO BB.5/28-OK TO POUR PROGRESS AREAS
09/18/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
WILL RECALL FOR 19 SEP
09/14/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
09/13/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINE L.8/9 TO L.8/14.4 @ 24";
SW STAIRWELL T.5/1 TO T.6/1 @ 48" -- OK TO POUR
09/11/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST ELEVATOR #2 SHAFT @ 4'; STEM WALL @ H/17 TO M/17
OK TO GROUT
09/07/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
09/06/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH ELEVATOR LINE T/15 @ 4';
LINE P/1 TO R/1; LINE F/11 TO G/14.4 @ 4'
OK TO GROUT PROGRESS AREAS
08/29/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
NOT READY -- WILL RECALL
08/27/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
STEM WALLS @ 0" TO 48" @ LINES G.5/8 TO L.1/1
O/1 TO U/1, U/1 TO T.5/14 -- OK TO GROUT
08/22/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*