Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T06CM05804
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/16/2008 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* ELEVATOR DOOR INFILLS AS PER RFI DATED 7 AUG 08 FLOORS 1-5 OK TO GROUT |
|
01/25/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* DUMPSTER AREA WALLS ALL TOPPED OUT @ 6'4" GROUTED -- OK TO CAP |
|
01/22/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1ST LIFT @ 0-4' EAST DUMPSTER OK TO POUR |
|
12/19/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL #1, ELEVATOR, ROOM #601: ALL @ 80'8" TOPPED OUT |
|
12/17/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LOBBY ELEVATOR 80'8"; 502-506 W,S,E WALLS @ 80'8" OK TO GROUT |
|
12/13/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR LINE G/2 TO G/9 @ 72'8"; ROOMS #502-506 WEST, NORTH, SOUTH WALLS @ 72'8" -- OK TO GROUT |
|
12/10/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LOBBY; #502-506; LINE G/1-5 TO 10.5; STAIRWELL #1 - ALL @ 72' -- OK TO GROUT |
|
12/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STAIRWELL #1 W-N-SOUTH WALLS @ 68'-72' ELEVATOR WALL @ 68'-72' -- OK TO GROUT |
|
12/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ROOMS #502-506, 64' TO 68'; NORTH, SOUTH, WEST WALLS: WEST ELEVATOR - STAIRWELL #1 - N.W.S WALLS 64' TO 68' OK TO GROUT PROGRESS AREAS (*) (*) - S.W MECHANICAL ROOM WALLS @ 0'-9'4" -- OK TO GROUT |
|
12/03/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* #502-506 @ 64'; 3RD FLOOR LOBBY #301 - 3' RADIUS WALL OK TO GROUT |
|
11/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ROOMS 502-506 @ 59'; #1 STAIRWELL WALLS @ 67'; WEST ELEVATOR @ 64' -- OK TO GROUT PROGRESS AREAS |
|
11/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STAIRS #1 & ELEVATOR @ 59' -- OK TO GROUT |
|
11/20/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LOBBY CMU WALL @ 64' - LINE G TO 9 |
|
11/19/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STAIRWELL #1, EAST WALL; LOBBY EAST WALL; ROOM #506 EAST WALL CHASE WALL EAST - ALL @ 59' - GRID LINE G/1.5 TO G/10.5 GROUTED |
|
11/13/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) STAIRWELL #1, ELEVATOR (WEST), #402-406 AT 55' |
|
11/08/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STAIRWELL #1, WEST ELEVATOR; ROOMS 402-406 ALL @ 50' -- OK TO GROUT |
|
11/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST ELEVATOR LOBBY WALL @ 50'; ROOM 402-406 @ 46' OK TO GROUT |
|
11/01/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR (WEST) LOBBY WALL @ 44' ROOM 302-306 @ 40' OK TO GROUT |
|
10/30/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST STAIRS @ 40'; ELEVATOR @ 40', ROOM #402-406 @ 36' OK TO GROUT |
|
10/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STAIRWELL #1 @ 36' VAIL PARKING LOT 4 @ LIGHT POLE COLUMN FOOTINGS OK TO POUR |
|
10/24/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STAIRWELL #1 @ 32'; G LINE 1.5 TO 10.5 @ 36' ROOM #302-306 @ 321 OK TO GROUT PROGRESS AREA |
|
10/22/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STAIRWELL #2 @ 32' INTERIOR WALL LINE G/1.5-10.5 @ ELEVATOR 32' OK TO GROUT |
|
10/19/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST STAIRWELL #1 @ 20'; INTERIOR MECHANICAL CHASE @ 31' EAST STAIRWELL CAPPED @ 68' OK TO GROUT - PROGRESS AREAS |
|
10/18/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2ND FLOOR MECHANICAL CHASE @ 19' -- OK TO GROUT |
|
10/17/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL INTERIOR WALLS @ 64' #1 STAIRWELL (WEST) @ 28' -- OK TO GROUT PROGRESS AREAS |
|
10/16/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL INTERIOR WALLS @ 64'; OK TO GROUT |
|
10/15/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL @ 74'4" (WEST WALL); LOBBY ENTRANCE @ 18' STAIRWELL #1 @ 20' -- OK TO GROUT |
|
10/11/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST ELEVATOR @ 74'8" TOPPED OUT OK TO CAP & GROUT |
|
10/10/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST ELEVATOR FASCIA WALL - 28' OK TO GROUT |
|
10/09/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST ELEVATOR @ 68' TO 72' LOBBY INTERIOR WALLS @ 28'8" -- OK TO GROUT |
|
10/08/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL @ 68'; OK TO GROUT |
|
10/04/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) LOBBY INTERIOR WALLS AT 28'; WEST ELEVATOR FACING AT 24' OK TO GROUT |
|
10/03/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LOBBY INTERIOR WALLS @ 20' - OK TO GROUT |
|
10/02/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL @ 64' WEST ELEVATOR - CMU WALLS @ 28' - LOBBY INTERIOR WALLS @ 18' - OK TO GROUT |
|
10/01/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* - EAST ELEVATOR @ 62', - WEST ELEVATOR (INTERIOR) FACING @ 20' - LOBBY INTERIOR WALLS @ 16' - OK TO GROUT PROGRESS AREAS * TRASH ENCLOSURE @ 6' - OK TO GROUT & CAP BENSON PARKING LOT - CONCRETE DRAINAGE GUTTER SE CORNER - MESH INSTALLED AS PER PLANS OK TO POUR |
|
09/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL @ 56'; LOBBY INTERIOR WALLS @ 12' OK TO GROUT |
|
09/25/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LOBBY ELEVATOR @ 18' OK TO GROUT |
|
09/24/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL @ 52' LOBBY INTERIOR WALLS @ 12' OK TO GROUT |
|
09/21/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL @ 48'; LOBBY EXTERIOR RADIUS WALL NW, LINE B.5/3.5 TO F.5/2.5; INTERIOR LOBBY WALLS @ 8' OK TO GROUT PROGRESS AREAS |
|
09/19/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) EAST STAIRS AT 44'; LOBBY EXTERIOR WALLS AT 18'; LOBBY INTERIOR WALLS AT 4'-OK TO GROUT PROGRESS AREA |
|
09/17/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL #2 @ 40' WEST MAIN ENTRY WALL - LINE A/3 TO C/11.5 @ 16' OK TO GROUT PROGRESS AREAS |
|
09/13/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL @ 36'; ELEVATOR FACE WALL @ 16' OK TO GROUT PROGRESS AREAS |
|
09/12/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL @ 32'; ELEVATOR FACE WALL @ MAIN ENTRY @ 12' -- OK TO GROUT |
|
09/10/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* WILL RECALL |
|
09/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL @ 28'; LOBBY WALLS @ 12' OK TO GROUT |
|
09/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL #2 @ 24'; LOBBY EXTERIOR WALLS @ 8' OK TO GROUT PROGRESS AREAS |
|
09/04/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* E. STAIRWELL (#2) @ 20' (EXTERIOR BRICK) LOBBY EXTERIOR WALLS & ENTRY AREA @ 4' ELEVATOR SHAFT (WEST) @ 20' : OK TO POUR |
|
08/28/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINES G/1 - 1.5 @ 18' 1/G TO M @ 18' M/1-7 @ 18' WEST STAIRWELL (W & N) WALLS @ 16' OK TO GROUT |
|
08/24/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH WALL @ 16' LINES G/1 TO 1.5 @ 16' COLUMN LINE 1-G TO M @ 16' COLUMN LINE M/1 - 7 @ 16' OK TO GROUT |
|
08/22/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH WALL LINE 12 G TO M G/11-12 M/11-12 @ 18' OK TO GROUT LINE 1 G TO M G/1 TO 1.5 M/1-7 @ 12' OK TO GROUT |
|
08/20/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) COLUMN LINE #1-G TO M; COLUMN LINE G/1 TO 1.5 ?/1 TO 7 AT 8'-OK TO GROUT |
|
08/16/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH WALL: LINE G-M; G/11-12 M/11-12 @ 16' -- OK TO GROUT |
|
08/14/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* COLUMN LINE 1/G TO "M" G/1 TO 1.5 M/1 TO 7 @ 4' OK TO GROUT |
|
08/13/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH WALL G-M @ 12' M/11 - M/12 G/11 - G/12 @ 12' OK TO GROUT PROGRESS AREA |
|
08/10/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) EAST STAIRWELL AT 28' LINE M/7 TO M/11 2) OK TO GROUT |
|
08/08/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH WALL LINE M/11-M/12 G/11 - G/12 @ 8' OK TO POUR |
|
08/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH WALL 11-12 (M) 11-12 (G) @ 4' OK TO GROUT |
|
08/06/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED RAINED OUT |
|
08/02/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL M-M.5; COLUMN LINE 7-11 @ 24' OK TO POUR |
|
07/31/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST STAIRWELL: G/1.5 TO G/11 @ 16' EAST STAIRWELL M/M.5; COLUMN LINE 7-11 @ 20' |
|
07/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL, CORRIDOR, STORAGE: LINES 7-11, M-M.5 @ 16' -- OK TO GROUT |
|
07/24/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* COLUMN LINE 1.5 TO 11; F-G; WEST STAIRWELL ELEVATOR BACK WALL TO RESTROOMS @ 8' |
|
07/23/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIR, CORRIDOR, STORAGE: LINES 7-11; M/5 @ 12' OK TO POUR |
|
07/19/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST STAIRWELL, LINE G/1.5 TO G/4 @ 8'; ELEVATOR WEST LINE G/4 TO G/9 @ 4' --- OK TO GROUT |
|
07/17/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STAIRWELL #2, EXIT VESTIBULE; STORAGE @ 8' - OK TO GROUT |
|
07/13/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST STAIRWELL @ 0'-4' OK TO GROUT |
|
07/11/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LOBBY - RESTROOMS (#101); ELECTRIC ROOM, JANITOR ROOM, MAIL ROOM @ 12"; VAULT N & E WALL @ FINISH FLOOR OK TO GROUT PROGRESS AREAS |
|
07/10/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST STAIRWELL #2 & STORAGE & VESTIBULE @ 4' OK TO GROUT |
|
06/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CANOPY COLUMNS @ 14' -- NW & SW OK TO GROUT |
|
06/27/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CANOPY COLUMNS NW/SW - NE/SE @ 12' OK TO GROUT |
|
06/20/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 4 @ CANOPY COLUMNS @ 4' ABOVE FINISH FLOOR OK TO GROUT |
|
06/11/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR CONTINUOUS SHELL STEM WALLS; 4 @ CANOPY COLUMNS, FIRST LIFT: OK TO POUR/GROUT |
|
05/31/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINE D/3 TO F.5/3; D/10 TO G/10 -- OK TO GROUT |
|
05/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WALL LINE #1 -- J TO K.5 (95' TO 99'4") STEM WALLS @ 91' TO 95' A TO G G/10.8 TO G/11.2 OK TO GROUT |