Permit: T06CM05164

Parcel: 127023460


Addresses:

755 N MAGNOLIA AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/07/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
1) SECURE EXTERIOR HBS, SHOULD HBS BE VANDAL PROOF ?
2) RM 113 CORRECT KINK IN CONDENSATE DRAIN
08/06/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LEAKS IN 153, 124 AND 113
2) WASHER BIB REQUIRES HAMMER ARRESTORS
3) CAULKING AT DF
08/05/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
ALL FIXTURES REQUIRE CAULK WHERE CONTACTING WALLS OR FLOORS, INCLUDING DFS

YOU STILL HAVE LEAKING WATER SUPPLY TUBES
08/01/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE STERILIZATION OF WATER SYSTEM
2. SECURE HBS
3. CORRECT DRIP AT WH SOV OK TO INSULATE
4. SECURE EXP. TANK - DRIPS ON LAV COMPRESSION FITTINGS
5. WATER TEST ALL FIXTURES
6. SEAL SINK
7. SHOWER PAN ISSUE NOT YET RECEIVED
8. NO PROB. FOR FURNITURE AS LONG AS PRECAUTIONS ARE IN PLACE TO PREVENT THE USE OF THE WATER UNTIL STERILIZATION IS COMPLETE