Permit: T06CM05164

Parcel: 127023460


Addresses:

755 N MAGNOLIA AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/06/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
07/22/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
CLOSET FLANGES OK
ONE MAY BE TOO HIGH
07/18/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
DOORS LOCKED
CEILING TILES INSTALLED
PROVIDE ACCESS FOR INSPECTION OF LABELS AND SHOWER PAN LINERS
06/27/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
05/13/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
STILL NEED PIPE LABELS AND CLOSET FLANGES.
LOOP HANGERS OK PER CLAYTON ENG.
04/22/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
04/08/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
DWV EAST BUILDING TEST OK
PLAN SPECIFIES CLEVUS OR UNISTRUT PIPE SUPPORTS
AND #227 PIPE
ISOLATORS ON ALL PIPING
ALSO, SPECIFIES PIPE LABELS
CORRECT SUPPORTS, SAFETY PLATES
OK TO INSULATE
PROVIDE OVERSIZED HANGERS AND CLEARANCE FOR INSULATION
02/28/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
ALL PLUMBING WALLS EXCEPT AT TRS 104 AND 169
OK TO COVER
02/20/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
REMOVE ALL CONCRETE TOUCHING PIPING
OK TO INSULATE WATER PIPING
TEST ENTIRE SYSTEM
02/15/2008 PLUMBING - INTERMEDIATE Cancelled
01/09/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
- PIPE RISERS W/TEST IN BLOCK WALLS
- PIPING WAS COVERED PRIOR TO INSPECTION
- PERMISSION TO PROCEED IS GIVEN
- TEST ENTIRE SYSTEM FROM EXT. CLEANOUT THRU ROOF FOR APPROVAL OF INTERMEDIATE
01/08/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
RICK W/BW PLUMBING
TEST ON WATER AND WASTE PIPING IN BLOCK WALLS NE SIDE
DO NOT COVER ANY MORE PIPES PRIOR TO TEST AND INSPECTION.
01/03/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
TEST ALL PIPING PRIOR TO COVERING IN BLOCK WALLS
NO GROUT IN CELLS W/PIPING
SEE SPECS FOR PIPE INSULATION