Permit: T06CM05164

Parcel: 127023460


Addresses:

755 N MAGNOLIA AV

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
06/17/2008 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
4 @ SCREEN WALLS TOPPED OUT @ 10'8"
OK TO GROUT AND CAP
06/12/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
4 @ SCREEN WALLS; D/8-J/11 @ 5'4"
03/03/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
5 @ PLUMBING CHASES - TOPPED OUT-- OK TO GROUT
02/29/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
9 @ PLUMBING CHASE WALLS @ 4' -- OK TO GROUT
02/21/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CLASSROOM #131 - SOUTH WALL @ 4' TO 8'8" -- OK TO GROUT
02/12/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MEDIA CENTER LINE B/8.5 TO E/4.5 CAPPED OUT @ 28'
OK TO GROUT & CAP
02/11/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CLASSROOMS #141, 144 -- OK TO POUR
02/08/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST MEDIA WALL @ 12' - GROUTED: A/8 TO E/6.5
02/07/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
INTERIOR WALL FROM CLASSROOM #144 TO #131 @ 18'
OK TO GROUT
02/04/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED-RAINED OUT
02/01/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EXTERIOR WALLS OF CLASSROOMS #134, 139, 141
TOPPED OUT @ 18' -- OK TO GROUT PROGRESS AREAS
01/31/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SW PORTION; #156 SOUTH, MEDIA ROOM #165, 171
EXTERIOR WALLS @ 17', RAKE WALLS @ 14'10" --
OK TO GROUT PROGRESS AREAS
01/30/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ROOM #156 NORTH EXTERIOR WALLS & RAKE WALLS @ 14'
OK TO GROUT
01/29/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CLASSROOMS #144, 147,
SOUTH WALL OF #141 @ 14'
OK TO GROUT PROGRESS AREAS
01/28/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
RAINED OUT
01/23/2008 REINFORCED MASONRY PRE-GROUT Partial Approval CLASSROOMS #110, 114 @ 18'
NE SECTION @ 22';
CLASSROOMS #131, 134, 139, 141 @ 8'8" TO 12'8" - OK TO POUR
01/18/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ WEST WALL HIGH LIFT 5'4" GROUT OK PER SPECIAL INSPECTOR @ ROOMS 110, 112, 113, 114, 115 AND 116 AND AT ROOMS 100, 101, 102, 103, 104, 105, 106, 107, 108, 109 & 111 TO 16'8" - OK TO GROUT
01/15/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NE PORTION CLASSROOMS #139, 134, 131 AND STORE ROOM
OK TO GROUT
01/11/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SE PORTION LINE D/2 - SOUTH - 8' TO 12'
OK TO GROUT PROGRESS AREAS
01/10/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SE PORTION - K/1.5 TO B/1.5; K/4.5 TO B/4.5
OK TO GROUT PROGRESS AREAS
01/04/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
01/03/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NE SECTION LINES E/14 TO P/10.5;
NW SECTION LINES N/10 TO E/2 - ALL @ 8'8" OK TO GROUT PROGRESS AREAS
01/02/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ROOMS #152-156 E&W WALLS @ 4'8"; LINES L17.5 - F/17 @ 8'8"
OK TO GROUT PROGRESS AREAS
12/31/2007 REINFORCED MASONRY PRE-GROUT Cancelled IVRS - RI canceled
12/27/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) STEM WALL AT 16" ROOMS #152-153; S.E. CLASS ROOM AREA AT 4'-8' OK TO GROUT
12/20/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTHWEST & SOUTH PORTION LINES B/2 TO B/8;
G/2 TO A/2 -- OK TO GROUT
12/18/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NE, NORTH, NW SECTIONS @ 4' -- OK TO GROUT
12/07/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST PORTION OF BUILDING @ 4' -- OK TO GROUT
11/27/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) STEM WALLS AT LINES N.5/10 TO N.5/2, N.5/2 TO NORTH, N.W. AND WEST PORTIONS OK TO GROUT
10/30/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
STEM WALL @ 16" - INTERIOR & EXTERIOR FOOTINGS
PERIMETER FOOTINGS EXCEPT NW CORNER - REBAR IN PLACE AS PER PLANS - OK TO GROUT