Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/17/2008 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* 4 @ SCREEN WALLS TOPPED OUT @ 10'8" OK TO GROUT AND CAP |
|
| 06/12/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 4 @ SCREEN WALLS; D/8-J/11 @ 5'4" |
|
| 03/03/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 5 @ PLUMBING CHASES - TOPPED OUT-- OK TO GROUT |
|
| 02/29/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 9 @ PLUMBING CHASE WALLS @ 4' -- OK TO GROUT |
|
| 02/21/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CLASSROOM #131 - SOUTH WALL @ 4' TO 8'8" -- OK TO GROUT |
|
| 02/12/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MEDIA CENTER LINE B/8.5 TO E/4.5 CAPPED OUT @ 28' OK TO GROUT & CAP |
|
| 02/11/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CLASSROOMS #141, 144 -- OK TO POUR |
|
| 02/08/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST MEDIA WALL @ 12' - GROUTED: A/8 TO E/6.5 |
|
| 02/07/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* INTERIOR WALL FROM CLASSROOM #144 TO #131 @ 18' OK TO GROUT |
|
| 02/04/2008 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* 1) CONTRACTOR CANCELLED-RAINED OUT |
|
| 02/01/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR WALLS OF CLASSROOMS #134, 139, 141 TOPPED OUT @ 18' -- OK TO GROUT PROGRESS AREAS |
|
| 01/31/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SW PORTION; #156 SOUTH, MEDIA ROOM #165, 171 EXTERIOR WALLS @ 17', RAKE WALLS @ 14'10" -- OK TO GROUT PROGRESS AREAS |
|
| 01/30/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ROOM #156 NORTH EXTERIOR WALLS & RAKE WALLS @ 14' OK TO GROUT |
|
| 01/29/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CLASSROOMS #144, 147, SOUTH WALL OF #141 @ 14' OK TO GROUT PROGRESS AREAS |
|
| 01/28/2008 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED RAINED OUT |
|
| 01/23/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CLASSROOMS #110, 114 @ 18' NE SECTION @ 22'; CLASSROOMS #131, 134, 139, 141 @ 8'8" TO 12'8" - OK TO POUR |
|
| 01/18/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU REINFORCEMENT STEEL @ WEST WALL HIGH LIFT 5'4" GROUT OK PER SPECIAL INSPECTOR @ ROOMS 110, 112, 113, 114, 115 AND 116 AND AT ROOMS 100, 101, 102, 103, 104, 105, 106, 107, 108, 109 & 111 TO 16'8" - OK TO GROUT |
|
| 01/15/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NE PORTION CLASSROOMS #139, 134, 131 AND STORE ROOM OK TO GROUT |
|
| 01/11/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SE PORTION LINE D/2 - SOUTH - 8' TO 12' OK TO GROUT PROGRESS AREAS |
|
| 01/10/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SE PORTION - K/1.5 TO B/1.5; K/4.5 TO B/4.5 OK TO GROUT PROGRESS AREAS |
|
| 01/04/2008 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED |
|
| 01/03/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NE SECTION LINES E/14 TO P/10.5; NW SECTION LINES N/10 TO E/2 - ALL @ 8'8" OK TO GROUT PROGRESS AREAS |
|
| 01/02/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ROOMS #152-156 E&W WALLS @ 4'8"; LINES L17.5 - F/17 @ 8'8" OK TO GROUT PROGRESS AREAS |
|
| 12/31/2007 | REINFORCED MASONRY PRE-GROUT | Cancelled | IVRS - RI canceled | |
| 12/27/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) STEM WALL AT 16" ROOMS #152-153; S.E. CLASS ROOM AREA AT 4'-8' OK TO GROUT |
|
| 12/20/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTHWEST & SOUTH PORTION LINES B/2 TO B/8; G/2 TO A/2 -- OK TO GROUT |
|
| 12/18/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NE, NORTH, NW SECTIONS @ 4' -- OK TO GROUT |
|
| 12/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST PORTION OF BUILDING @ 4' -- OK TO GROUT |
|
| 11/27/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) STEM WALLS AT LINES N.5/10 TO N.5/2, N.5/2 TO NORTH, N.W. AND WEST PORTIONS OK TO GROUT |
|
| 10/30/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STEM WALL @ 16" - INTERIOR & EXTERIOR FOOTINGS PERIMETER FOOTINGS EXCEPT NW CORNER - REBAR IN PLACE AS PER PLANS - OK TO GROUT |