Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/11/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1. YOU HAVE AN APPROVED SITE PLAN. NOW YOU NEED AN APPROVED SITE UTILITY PLAN. 2. OK TO COVER ALL AREAS INSIDE 3. YARDWATER OK TO COVER YARD |
|
| 09/09/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. ABS WATER TEST OK 2. CLOSET BENDS RE-ROUGHED OK - OK TO COVER 3. ALL PIPING TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE ENDS OF BRANCHES THEN NO MORE THAN FOUR FEET BETWEEN HANGERS 4. ABS TO BE PROTECTED FROM METAL STUDS. HANGERS PER PLAN. 5. REQUIRE APPROVED SITE UTILITY PLAN. |
|
| 09/08/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* DWV NOT UNDER TEST SWEEPS REQUIRED ON TRAP ARMS SAFETY PLATES MISSING INSTALL BACKING FOR MS |