Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/02/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 03/27/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE A TEMPERING VALVE FOR PUBLIC USE LAV HOT SIDE 2. RECEIVED CLEAN BACTERIA REPORT |
|
| 03/26/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE MEANS FOR WATER HAMMERING AT WASHER BOX 2. PROVIDE VACUUM BREAKER AT SHOWER 3. COMPLETE LABELING NEED GAS PIPING 4. LIST NOT COMPLETE |
|
| 03/24/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |