Permit: T06CM04580

Parcel: 117032710

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T06CM04580

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/19/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
10/05/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
COMPLETE ALL CORRECTIONS BEFORE FINAL
09/21/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. SMOKE DETECTORS NEEDED IN EVERY ROOM & HALLWAY (BEDROOM) WORKING AND PROPERLY INSTALLED INTERCONNECTED THROUGH STRUCTURE.
2. NEED GFI PROTECTION FOR ALL BATHROOM AND KITCHEN COUNTER AND EXTERIOR RECEPTACLES.
3. IDENTIFY ALL PANEL DIRECTORY'S AND FILL OPEN BREAKER SPACES.
4. HAVE 3 WIRE RECEPTACLES WITHOUT GROUND THROUGOUT.
5. HAVE SHOWER LIGHTING FIXTURES THAT ARE NOT PER CODE.
6. HAVE OPEN BROKEN WIRING THROUGHOUT
7. USE ONLY BREAKERS LISTED FOR PANELS
8. NEED WORKING LIGHT OR SWITCHED RECEPTACLE IN ALL HABITABLE ROOMS CONTROL BY WALL SWITCH.
9. OPEN WIRING THROUGHOUT ATTIC & BASEMENT.

USE QUALIFIED CONTRACTOR/PERMIT