Inspection History Details
Inspection Status: Approved
Inspection History: SITE - SEWER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/23/2007 | SITE - SEWER | Approved | ||
| 11/03/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. VACUUM TEST OK 2. TEST REPORT PROVIDED |
|
| 10/27/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* FLOW TEST FROM 45 DEG. TO TIE IN AT SADDLE TRAP OK |
|
| 10/26/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. SADDLE INSTALLED TEST ON 6" PVC TO 45 DEG. 20' BACK FROM MANHOLE TEST OK 2. CALL FOR RUN TEST ON PIPING TO TIE-IN 3. PROVIDE APPROVED PLANS ON SITE. 4. PROVIDE VACUUM TEST ON MANHOLE 5. 6" PVC TO BUILDING TEST OK 6. PROVIDE GRADE INFO REC'D CHECK #013112 FOR UNSCHEDULED INSPECTION. |
|
| 10/24/2006 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* THIS INSPECTION IS FOR PRE-CONSTRUCTION MEETING BEDDING, LAYING, SHADING PLAN IS APPROVED IN ERROR 31% FALL FOR 6" TIE INTO 10" MAIN SEWER DOES NOT MEET PIMA COUNTY WASTEWATER DETAIL #401 THIS INSTALLATION SHALL MEET PIMA COUNTY WASTEWATER STANDARDS 2003 EDITION PER PLAN C1.5 PIPING WILL REQUIRE TESTING, MANHOLE TO PROVIDE VACUUM TESTING, SHALL HAVE VERIFICATION OF GRADE FROM ENGINEER OR LICENSED SURVEYOR. |